SIEMENS
2/13
Siemens CR 1 · 2015
2
■
Technical specifications
(continued)
SIMOCRANE Standard Technology
SIMOCRANE Basic Technology
Hardware SIMOTION CX32-2 Controller Extension
6AU1432-2AA00-0AA0
Product brand name
SIMOTION
Product-type designation
CX32-2
Version of the motion control system
Controller Extension
Digital inputs
Number of digital inputs
6
DC input voltage
• rated value
V
24
• for signal "1"
V
15 … 30
• for signal "0"
V
-3 … +5
Electrical isolation
Yes
• remark
in groups of 6
Current consumption for "1" signal level, typ.
mA
9
Input delay for
• signal "0"
→
"1", typ.
μs
50
• signal "1"
→
"0", typ.
μs
150
Digital inputs/outputs
Number of digital inputs/outputs
4
Parameterization possibility
of the digital inputs/outputs
parameterizable as DI, as DO, as probe input (max. 4)
If used as an input
DC input voltage
• rated value
V
24
• for signal "1"
V
15 … 30
• for signal "0"
V
-3 … +5
Electrical isolation
No
Current consumption for "1" signal level, typ.
mA
9
Input delay for
• signal "0"
→
"1", typ.
μs
5
• signal "1"
→
"0", typ.
μs
50
Measuring input, reproducibility
μs
5
Measuring input, resolution
μs
1
If used as an output
Load voltage
rated value
V
24
Load voltage
minimum
V
20.4
Load voltage
maximum
V
28.8
Electrical isolation
No
Current carrying capacity for each output, max.
mA
500
Leakage current, max.
mA
2
Output delay for
• signal "0"
→
"1", typ.
μs
150
• signal "0"
→
"1", max.
μs
400
• signal "1"
→
"0", typ.
μs
75
• signal "1"
→
"0", max.
μs
100
- remark
Data for V
cc
= 24 V; load 48 Ohm; "1" = 90 % V
Out
, "0" = 10 % V
Out
Switching frequency of the outputs for
• ohmic load, max.
Hz
100
• inductive load, max.
Hz
2
• lamp load, max.
Hz
11
Short-circuit protection
Yes
Additional technical specifications
Backup of non-volatile data
• Backup of retentive data
unlimited buffer duration
Approvals
• USA
cULus
• Canada
cULus
• Australia
C-Tick
• Korea
KCC
© Siemens AG 2015