Drive systems
SINAMICS S120 built-in devices
Active Line Modules in booksize format
■
Overview
Active Line Modules are self-commutated feed/feedback units
(with IGBTs in infeed and regenerative feedback directions) and
generate a regulated DC link voltage. This means that the con-
nected Motor Modules are decoupled from the line voltage. Line
voltage fluctuations within the permissible supply tolerances
have no effect on the motor voltage. Active Line Modules are
designed for connection to grounded, star (TN, TT) and non-
grounded, symmetrical IT systems.
The DC link is pre-charged via integrated pre-charging resistors.
In order to operate an Active Line Module, it is absolutely
essential to use the appropriate Active Interface Module.
■
Design
The Active Line Modules in booksize format feature the following
connections and interfaces as standard:
•
1 power connection via screw-type terminals
•
1 connection for the 24 V DC electronics power supply via the
24 V terminal adapter included in the scope of supply
•
1 DC link connection via integrated DC link busbars
•
3 DRIVE-CLiQ sockets
•
2 PE (protective earth) connections
The status of the Active Line Modules is indicated via two multi-
color LEDs.
On the 100 mm (3.94 in) wide Active Line Module, the shield for
the power supply cable can be connected to the integrated
shield connection plate via a shield connection terminal or tube
clip, e.g. Weidmüller type KLBÜ CO 4. The shield connection
terminal must not be used for strain relief. Shield connection pla-
tes are available for the 150 mm (5.91 in), 200 mm (7.87 in) and
300 mm (11.81 in) wide modules.
The signal cable shield can be connected to the Line Module by
means of a shield connection terminal, e.g. Weidmüller type
KLBÜ 3-8 SC.
The scope of supply of the Active Line Modules includes:
•
DRIVE-CLiQ cable for connection to the adjacent Control Unit
on the left for drive control, length 0.11 m (4.33 in)
•
DRIVE-CLiQ cable (length depends on module width) to
connect Active Line Module to adjacent Motor Module,
length = width of Active Line Module + 0.11 m (4.33 in)
•
2 blanking plugs for sealing unused DRIVE-CLiQ sockets
•
Jumper for connecting the 24 V DC busbar to the adjacent
Motor Module
•
24 V terminal adapter (X24)
•
Connector X21 for digital inputs
•
Fan insert for Active Line Modules of 80 kW (107 hp) and
120 kW (161 hp) (the voltage is supplied by the Active Line
Module)
•
1 set of warning signs in 30 languages
•
1 heat conducting foil
(for Active Line Modules with cold plate cooling only)
■
Selection and ordering data
Accessories
For technical specifications, selection and ordering data for the
line reactors, Wideband Line Filters, Basic Line Filters and the
recommended line-side components, see Catalog PM 21, Chap-
ter 3 "Active Line Modules in booksize format".
■
More information
For detailed technical information, see Catalog PM 21,
Chapter 3 "Active Line Modules in booksize format".
Active Line Module
in booksize format
Description
Article No.
Line voltage 380 ... 480 V 3 AC
Internal air cooling
Rated power
• 16 kW (18 hp)
6SL3130-7TE21-6AA3
• 36 kW (40 hp)
6SL3130-7TE23-6AA3
• 55 kW (60 hp)
6SL3130-7TE25-5AA3
• 80 kW (100 hp)
6SL3130-7TE28-0AA3
• 120 kW (150 hp)
6SL3130-7TE31-2AA3
External air cooling
Rated power
• 16 kW (18 hp)
6SL3131-7TE21-6AA3
• 36 kW (40 hp)
6SL3131-7TE23-6AA3
• 55 kW (60 hp)
6SL3131-7TE25-5AA3
• 80 kW (100 hp)
6SL3131-7TE28-0AA3
• 120 kW (150 hp)
6SL3131-7TE31-2AA3
Cold-plate cooling
Rated power
• 16 kW (18 hp)
6SL3136-7TE21-6AA3
• 36 kW (40 hp)
6SL3136-7TE23-6AA3
• 55 kW (60 hp)
6SL3136-7TE25-5AA3
• 80 kW (100 hp)
6SL3136-7TE28-0AA3
• 120 kW (150 hp)
6SL3136-7TE31-2AA3
Liquid cooling
Rated power
• 120 kW (150 hp)
6SL3135-7TE31-2AA3