6/57
Siemens CR 1 · 2015
6
Drive systems
SINAMICS S120 Cabinet Modules
Active Line Modules including Active Interface Modules
■
Technical specifications
Line voltage 380 … 480 V 3 AC
Active Line Module
Type
6SL3730-7TE35-0BA3
6SL3730-7TE38-4BA3
6SL3730-7TE41-0BA3
6SL3730-7TE41-4BA3
For parallel connection, mounted to the
left of the Line Connection Module
6SL3730-7TE41-0BC3
6SL3730-7TE41-4BC3
Rated output
• at
I
rated DC
(50 Hz 400 V)
kW
300
500
630
900
• at
I
H DC
(50 Hz 400 V)
kW
270
465
545
780
• at
I
rated DC
(60 Hz 460 V)
hp
500
700
900
1250
• at
I
H DC
(60 Hz 460 V)
hp
400
700
800
1000
DC link current
• Rated current
I
rated DC
A
549
940
1103
1574
• Base-load current
I
H DC
1)
A
489
837
982
1404
• Maximum current
I
max DC
A
823
1410
1654
2361
Infeed/regenerative feedback current
• Rated current
I
rated E
A
490
840
985
1405
• Maximum current
I
max E
A
735
1260
1477
2107
Power requirement
• 24 V DC aux. power supply
A
1.52
1.57
1.67
1.67
• 400 V AC
A
1.8
3.6
5.4
5.4
DC link capacitance
• Active Line Module
μ
F
9600
16800
18900
28800
• Drive line-up, max.
μ
F
76800
134400
230400
230400
Power loss, max.
2)
• at 50 Hz 400 V
kW
8.7
13.8
17.6
21.8
• at 60 Hz 460 V
kW
9.0
14.3
18.3
22.7
Cooling air requirement
m
3
/s
1.3
1.58
1.88
1.88
Sound pressure level
L
pA
3)
(1 m) at 50/60 Hz
dB
72/74
77/79
78/80
78/80
PE/GND connection
PE bar
PE bar
PE bar
PE bar
• Busbar cross-section
mm
2
600
600
600
600
• Conductor cross-section, max. (IEC)
mm
2
240
240
240
240
Cable length, max.
4)
• Shielded
m
2700
3900
3900
3900
• Unshielded
m
4050
5850
5850
5850
Degree of protection
IP20
IP20
IP20
IP20
Dimensions
• Width with option
B70
mm
1000
1200
1600
1600
• Height
5)
mm
2200
2200
2200
2200
• Depth
mm
600
600
600
600
Weight, approx.
kg
530
930
1360
1360
Frame size
GX + GI
HX + HI
JX + JI
JX + JI
1)
The base-load current
I
H DC
is based on a duty cycle of 150 % for 60 s
or
I
max DC
for 5 s with a duty cycle duration of 300 s.
2)
The specified power loss represents the maximum value at 100 % utiliza-
tion. The value is lower under normal operating conditions.
3)
Total sound pressure level of Active Interface Module and Active Line
Module.
4)
Total of all motor cables and DC link. Longer cable lengths for specific
configurations are available on request.
5)
The cabinet height increases by 250 mm with IP21 degree of protection,
and by 400 mm with IP23 degree of protection.
© Siemens AG 2015