siemens industrial communication, siemens catalogues, siemens supplier, siemens distributor

Thousands of wholesale products available. Trusted Brands. Expertise. Support.

Save time and money! Contact us to buy now at +39 080.5367090 info@tecnicaindustriale.com

Siemens Industrial Communication – page 84

SIEMENS
logo_siemens

Siemens catalogues

Click here for immediate price quote or call us at +39 080.5367090

3/82
Siemens IK PI · 2015
PROFIBUS
Electrical networks (PROFIBUS PA)
Active field distributors
3
■
Technical specifications
Active field distributor (AFD)
General data
Connection of field devices
• Standard-compliant field devices
for PROFIBUS PA or FOUNDATION
Fieldbus H1
• Max. 4 per AFD4
• Max. 8 per AFD8
• Max. 31 per fieldbus segment
•
Operating environment up to Zone
2
oder 22; Class I Zone 2/ Division 2
• The max. current consumption of all
fieldbus components of the fieldbus
segment is 1 A
Degree of protection
IP66
Voltages, currents, potentials
Power supply
Via bus, no auxiliary power necessary
Rated supply voltage, permissible
range
16 ... 32 V DC
Reverse polarity protection
(together with FDC 157)
Yes
Overvoltage protection
No
Current consumption
• Current consumption at idle
AFD4: 24 mA
AFD8: 34 mA
• Current consumption with
connected field devices
AFD4: 24 mA
+ total current of all field devices
AFD8: 34 mA
+ total current of all field devices
• Additional current consumption of
the AFD at end of line
(an open main line connection)
30 mA
• Current consumption at
max. power output per spur line
AFD4: 264 mA
AFD8: 514 mA
Power loss
AFD4: Min. 384 mW; max. 3.2 W
AFD8: Min. 544 mW; max. 4.1 W
Grounding
Direct, via grounding rail
Electrical isolation between
main line and spur lines
No
Connections, interfaces
Main line
Number of connections
2
Interfaces
PROFIBUS PA and
FOUNDATION Fieldbus H1
Automatic bus terminator
Yes
Spur cables
Number of connections
• AFD4
4
• AFD8
8
Short-circuit-proof
Yes
Intrinsically-safe acc. to FISCO
No
Current I
max
(DC) on spur lines
1 to 4 (AFD4) or 1 to 8 (AFD8)
60 mA
Short-circuit current (test current)
6 mA
Debounce logic
Yes
No-load voltage
< 30 V
Current output to field devices
• AFD4
Max. 240 mA
• AFD8
Max. 480 mA
Status, interrupts, diagnostics
Status indicator
Yes
Diagnostics function
Yes
Diagnostics LED
Yes
Interrupts
No
Climatic conditions
Permissible operating temperature
-40 ... +70 °C
Permissible storage/transport
temperature
-40 ... +85 °C
Relative humidity during operation
Max. 95 %
Approvals for potentially explosive
atmospheres
• Gas
Zone 2
• Dust
Zone 22
Dimensions and weight
Dimensions (W x H x D) in mm
(without fittings)
• AFD4
220 x 120 x 83
• AFD8
360 x 120 x 83
Weight
• AFD4
2 000 g
• AFD8
3 000 g
Active field distributor (AFD)
© Siemens AG 2014
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 25 - 26 - 27 - 28 - 29 - 30 - 31 - 32 - 33 - 34 - 35 - 36 - 37 - 38 - 39 - 40 - 41 - 42 - 43 - 44 - 45 - 46 - 47 - 48 - 49 - 50 - 51 - 52 - 53 - 54 - 55 - 56 - 57 - 58 - 59 - 60 - 61 - 62 - 63 - 64 - 65 - 66 - 67 - 68 - 69 - 70 - 71 - 72 - 73 - 74 - 75 - 76 - 77 - 78 - 79 - 80 - 81 - 82 - 83 - 84 - 85 - 86 - 87 - 88 - 89 - 90 - 91 - 92 - 93 - 94 - 95 - 96 - 97 - 98 - 99 - 100 - 101 - 102 - 103 - 104 - 105 - 106 - 107 - 108 - 109 - 110 - 111 - 112 - 113 - 114 - 115 - 116 - 117 - 118 - 119 - 120 - 121 - 122 - 123 - 124 - 125 - 126 - 127 - 128 - 129 - 130 - 131 - 132 - 133 - 134 - 135 - 136 - 137 - 138 - 139 - 140 - 141 - 142 - 143 - 144 - 145 - 146 - 147 - 148 - 149

Ask for a free quotation – We are at your disposal

Call us at +39 080.5367090 or send an email to info@tecnicaindustriale.com