3/144
Siemens IK PI · 2015
PROFIBUS
Optical networks with OBT and integrated interface
Optical bus terminal OBT
3
■
Integration
System configuration of optical PROFIBUS DP with PROFIBUS OBT
■
Technical specifications
PC/IPC/OP
with CP 5613 A2 /
CP 5623
S7-300
with CP 342-5 FO
ET 200S
with IM 151 FO
ET 200M
with IM 153-2 FO
DP node
without integrated optics
Individual link lengths: plastic up to 50 m,
PCF up to 300 m
Connecting cable
830-1T
Other
nodes
Connecting
cable 830-1T
Other nodes
PROFIBUS (Fiber Optic)
G_IK10_XX 50107
OBT
OBT
Article No.
6GK1500-3AA10
Product-type designation
PROFIBUS OBT
Transmission rate
Transfer rate
• with PROFIBUS
9.6 kbit/s … 12 Mbit/s
• With PROFIBUS PA
45.45 kbit/s
Interfaces
Number of electrical/optical connec-
tions for network components or
terminal equipment maximum
3
Number of electrical connections
• for network components and
terminal equipment
1
• for power supply
1
Design of electrical connection
• for network components and
terminal equipment
9-pin Sub-D socket
• for power supply
3-pole terminal block
Number of optical interfaces
for optical waveguide
2
Design of the optical interface
for optical waveguide
Duplex port
Optical data
Damping ratio of FOC transmission
link
• for PCF FOC with 200/230 μm
at 10 dB/km
3 dB
• for POF FOC with 980/1 000 μm
at 230 dB/km
13 dB
Signal delay time in bit time
6.5 bit
Injectable optical power relating
to 1 mW of FOC transmission link
• for PCF FOC with 200/230 μm
at 10 dB/km
-16 dB
• for POF FOC with 980/1 000 μm
at 230 dB/km
-5.9 dB
Optical sensitivity relating to 1 mW
of FOC transmission link
• for PCF FOC with 200/230 μm
at 10 dB/km
-22 dB
• for POF FOC with 980/1 000 μm
at 230 dB/km
-20 dB
Wavelength of FOC transmission link
• for PCF FOC with 200/230 μm
at 10 dB/km
660 nm
• for POF FOC with 980/1 000 μm
at 230 dB/km
660 nm
Cable length
• for PCF FOC with 200/230 μm
at 10 dB/km maximum
300 m
• for POF FOC with 980/1 000 μm
at 230 dB/km maximum
50 m
Supply voltage, current
consumption, power loss
Type of supply voltage
DC
Supply voltage for DC
• rated value
24 V
• minimum
19.2 V
• maximum
28.8 V
Product component fusing
at power supply input
-
Type of fusing at input for
supply voltage
-
Consumed current At 24 V with DC
maximum
-
Active power loss at 24 V for DC
-
Permitted ambient conditions
Ambient temperature
• during operating
0 … 60 °C
• during storage
-40 … +70 °C
• during transport
-40 … +70 °C
Relative humidity at 25 °C
without condensation during
operating maximum
95 %
Protection class IP
IP30
Article No.
6GK1500-3AA10
Product-type designation
PROFIBUS OBT
© Siemens AG 2014
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 25 - 26 - 27 - 28 - 29 - 30 - 31 - 32 - 33 - 34 - 35 - 36 - 37 - 38 - 39 - 40 - 41 - 42 - 43 - 44 - 45 - 46 - 47 - 48 - 49 - 50 - 51 - 52 - 53 - 54 - 55 - 56 - 57 - 58 - 59 - 60 - 61 - 62 - 63 - 64 - 65 - 66 - 67 - 68 - 69 - 70 - 71 - 72 - 73 - 74 - 75 - 76 - 77 - 78 - 79 - 80 - 81 - 82 - 83 - 84 - 85 - 86 - 87 - 88 - 89 - 90 - 91 - 92 - 93 - 94 - 95 - 96 - 97 - 98 - 99 - 100 - 101 - 102 - 103 - 104 - 105 - 106 - 107 - 108 - 109 - 110 - 111 - 112 - 113 - 114 - 115 - 116 - 117 - 118 - 119 - 120 - 121 - 122 - 123 - 124 - 125 - 126 - 127 - 128 - 129 - 130 - 131 - 132 - 133 - 134 - 135 - 136 - 137 - 138 - 139 - 140 - 141 - 142 - 143 - 144 - 145 - 146 - 147 - 148 - 149