7/50
Siemens IK PI · 2015
Industrial Remote Communication
TeleControl Professional for the control center
PCS 7 TeleControl Operator System
7
■
Overview
Uniform process control for central and remote units
The PCS 7 TeleControl OS software packages offered for
OS runtime mode are tailored to the architecture of the
SIMATIC PCS 7 operator system. They support single-user
systems (single stations) as well as multi-user systems with
up to 12 servers/redundant pairs of servers and up to 32 clients.
■
Design
PCS 7 TeleControl OS servers and PCS 7 TeleControl OS single
stations can integrate both local SIMATIC PCS 7 automation sys-
tems and widely distributed outstations (RTUs) of a telecontrol
system into the process control.
Depending on the configuration of a PCS 7 TeleControl operator
system as single station or client/server combination (single or
redundant), the following software components are required:
Ordering data for SIMATIC PCS 7 OS Runtime licenses for
expanding the OS Runtime POs (single station/server) and
additional SIMATIC PCS 7 OS software components for PCS 7
TeleControl Operator Systems can be found in Catalog
ST PCS 7, Chapter "Operator system", section "OS software".
SIMATIC PCS 7 Industrial Workstations suitable as basic
hardware for configuration of an operator station as PCS 7
TeleControl OS single station, PCS 7 TeleControl OS server or
PCS 7 TeleControl OS client can be found in Catalog ST PCS 7,
section "Industrial Workstation/PC".
PCS 7 TeleControl OS software for single station,
server and redundant server
The software product PCS 7 TeleControl OS Runtime contains
the PCS 7 TeleControl OS software including the object library
with the PCS 7 TeleControl OS faceplates and symbols as well
as the Runtime license for operation on an OS single station
or OS server.
An additional PCS 7 TeleControl Driver license is required
for each telecontrol protocol used (SINAUT, DNP3,
IEC 60870-5-101/-104, Modbus RTU, S7 EDC) per PCS 7
TeleControl OS single station and per PCS 7 TeleControl
OS server.
The SIMATIC PCS 7 OS Software must be ordered separately.
You can find the SIMATIC PCS 7 OS software for OS single sta-
tion and OS server in section "Operator system", "OS software",
and the SIMATIC PCS 7 OS software for a redundant pair of
OS servers (including RS 232 cable, 10 m) in Catalog ST PCS 7,
section "Operator system", "OS redundancy".
Upgrade
Existing SIMATIC PCS 7 TeleControl OS Runtime Software V7.1
can be upgraded from V7.1 to V8.0 (incl. service pack) using the
SIMATIC PCS 7 TeleControl Upgrade Package. This is also suit-
able for upgrading the SIMATIC PCS 7 TeleControl OS Engineer-
ing Software V7.1. The SIMATIC PCS 7 ES and OS Software V7.1
combined in certain software products must be upgraded
separately to V8.0 (incl. service pack) using the upgrade pack-
ages in Catalog ST PCS 7, sections "Upgrades for engineering
system" and "Upgrades for operator system".
Software required
SIMATIC PCS 7 architecture
OS single station
Client server
Client
Server not redundant
Server redundant
PCS 7 OS Software Single Station V8.0 (incl. SP)
see section "OS software" in the Chapter "Operator system"
•
–
–
–
PCS 7 OS Software Server V8.0 (incl. SP)
see section "OS software" in the Chapter "Operator system"
–
–
•
–
PCS 7 OS Software Server Redundancy V8.0 (incl. SP)
see section "OS software" in the Chapter "Operator system"
–
–
–
•
PCS 7 OS Software Client V8.0 (incl. SP)
see section "OS software" in the Chapter "Operator system"
–
•
–
–
PCS 7 TeleControl OS Runtime V8.0 (incl. SP)
•
–
•
• (2 licenses)
PCS 7 TeleControl Driver
(alternative)
SINAUT
•
–
•
• (2 licenses)
DNP3
•
–
•
• (2 licenses)
IEC 60870-5-101/-104
•
–
•
• (2 licenses)
Modbus RTU
•
–
•
• (2 licenses)
S7 EDC
•
–
•
• (2 licenses)
© Siemens AG 2014
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 25 - 26 - 27 - 28 - 29 - 30 - 31 - 32 - 33 - 34 - 35 - 36 - 37 - 38 - 39 - 40 - 41 - 42 - 43 - 44 - 45 - 46 - 47 - 48 - 49 - 50 - 51 - 52 - 53 - 54 - 55 - 56 - 57 - 58 - 59 - 60 - 61 - 62 - 63 - 64 - 65 - 66 - 67 - 68 - 69 - 70 - 71 - 72 - 73 - 74 - 75 - 76 - 77 - 78 - 79 - 80 - 81 - 82 - 83 - 84 - 85 - 86 - 87 - 88 - 89 - 90 - 91 - 92 - 93 - 94 - 95 - 96 - 97 - 98 - 99 - 100 - 101 - 102 - 103 - 104 - 105 - 106 - 107 - 108 - 109 - 110 - 111 - 112 - 113 - 114 - 115 - 116 - 117 - 118 - 119 - 120 - 121 - 122 - 123 - 124 - 125 - 126 - 127 - 128 - 129 - 130 - 131 - 132 - 133 - 134 - 135 - 136 - 137 - 138 - 139 - 140 - 141 - 142 - 143 - 144 - 145 - 146 - 147 - 148 - 149 - 150 - 151 - 152 - 153 - 154 - 155 - 156 - 157 - 158 - 159 - 160 - 161 - 162 - 163 - 164 - 165 - 166 - 167 - 168 - 169 - 170 - 171 - 172 - 173 - 174 - 175 - 176 - 177 - 178 - 179 - 180 - 181 - 182 - 183 - 184 - 185 - 186 - 187 - 188 - 189 - 190 - 191 - 192 - 193 - 194 - 195 - 196 - 197 - 198 - 199 - 200 - 201 - 202