Siemens IK PI · 2015
Industrial Wireless Communication
IWLAN – Accessories
KEY-PLUG W700
6
■
Overview
•
Swap medium with which iFeatures are enabled
•
If a fault occurs, it allows fast and simple device replacement
of SCALANCE W components without a PG
•
Can be used in all SCALANCE W700 IEEE 802.11n products
with a PLUG compartment
•
For the automatic backup of configuration data
■
Benefits
•
Fast and simple replacement of SCALANCE W components
without reconfiguration of the spare part.
•
The device can be replaced without the need for specially
trained personnel or a programming device or PC.
•
The downtimes of network segments and connected Industrial
Ethernet nodes can therefore be minimized if a fault occurs.
■
Application
The KEY-PLUG stores the configuration data of a SCALANCE W
component. In addition, the iFeatures are enabled.
In addition to this, if there is a fault on a module, the module can
be replaced simply and quickly without needing to reconfigure
the replacement device and without specially trained personnel.
If a device needs to be replaced, the KEY-PLUG is simply re-
moved from the failed component and plugged into the replace-
ment device. The replacement device installed in the network
now starts up automatically with the same device configuration
as the failed device.
■
Design
The KEY-PLUG has degree of protection IP20. The degree of
protection of IP65 components is ensured by the design of the
target device. The KEY-PLUG is inserted in the PLUG compart-
ment of the SCALANCE W component.
■
Mode of operation
During startup, the device automatically backs up the configura-
tion data on a KEY-PLUG (as-supplied from the factory) plugged
into a SCALANCE W component. Changes to the configuration
during operation are also saved on the KEY-PLUG without any
additional operator intervention being necessary.
During startup, an unconfigured device automatically loads the
configuration data from an inserted KEY-PLUG that has been
written to provided the data was written by a compatible device
type.
Diagnostics
Incorrect use of the KEY-PLUG, such as inserting a KEY-PLUG
containing the configuration of a different device group or
general malfunctions of the KEY-PLUG are indicated by
diagnostics mechanisms of the host device (LEDs, SNMP,
Web based Management, etc.).
© Siemens AG 2014
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 25 - 26 - 27 - 28 - 29 - 30 - 31 - 32 - 33 - 34 - 35 - 36 - 37 - 38 - 39 - 40 - 41 - 42 - 43 - 44 - 45 - 46 - 47 - 48 - 49 - 50 - 51 - 52 - 53 - 54 - 55 - 56 - 57 - 58 - 59 - 60 - 61 - 62 - 63 - 64 - 65 - 66 - 67 - 68 - 69 - 70 - 71 - 72 - 73 - 74 - 75 - 76 - 77 - 78 - 79 - 80 - 81 - 82 - 83 - 84 - 85 - 86 - 87 - 88 - 89 - 90 - 91 - 92 - 93 - 94 - 95 - 96 - 97 - 98 - 99 - 100 - 101 - 102 - 103 - 104 - 105 - 106 - 107 - 108 - 109 - 110 - 111 - 112 - 113 - 114 - 115 - 116 - 117 - 118 - 119 - 120 - 121 - 122 - 123 - 124 - 125 - 126 - 127 - 128 - 129 - 130 - 131 - 132 - 133 - 134 - 135 - 136 - 137 - 138 - 139 - 140 - 141 - 142 - 143 - 144 - 145 - 146 - 147 - 148 - 149 - 150 - 151 - 152 - 153 - 154 - 155 - 156 - 157 - 158 - 159 - 160 - 161 - 162 - 163 - 164 - 165 - 166 - 167 - 168 - 169 - 170 - 171 - 172 - 173 - 174 - 175 - 176 - 177 - 178 - 179 - 180 - 181 - 182 - 183 - 184 - 185 - 186 - 187 - 188 - 189 - 190 - 191 - 192 - 193 - 194 - 195 - 196 - 197 - 198 - 199 - 200 - 201 - 202