siemens industrial communication, siemens catalogues, siemens supplier, siemens distributor

Thousands of wholesale products available. Trusted Brands. Expertise. Support.

Save time and money! Contact us to buy now at +39 080.5367090 info@tecnicaindustriale.com

Siemens Industrial Communication – page 184

SIEMENS
logo_siemens

Siemens catalogues

Click here for immediate price quote or call us at +39 080.5367090

7/45
Siemens IK PI · 2015
Industrial Remote Communication
TeleControl Professional for the control center
PCS 7 TeleControl
7
■
Benefits
•
SIMATIC PCS 7 TeleControl cannot only integrate newly
configured RTUs into SIMATIC PCS 7, but also migrate units
which already exist in outdoor areas.
•
As a result of its high level of integration, automation based on
SIMATIC PCS 7 TeleControl offers decisive advantages
compared to previous automation solutions with telecontrol
engineering.
- The uniform SIMATIC PCS 7 software platform allows high
efficiency during operation, and results in low costs for
training, configuration and servicing.
- The homogenous GUI for local and remote processes
simplifies operation and simultaneously reduces the risk of
an operator error.
•
The Data Base Automation (DBA) software efficiently supports
engineering and takes into account the conformity with
SIMATIC PCS 7.
- DBA considerably facilitates project-specific adaptation of
the system and importing of existing configurations in the
course of migration.
- Extensions can be added during plant operation.
■
Application
Remote control and monitoring of distributed stations, as well as
data recording and transmission, with the following focal points:
•
Water industry
- Well, pumping and slide valve stations in water supply
networks and irrigation plants
- Pumping and slide valve stations in water and wastewater
pipelines
- Storm-water tanks and siphon stations in wastewater
networks
- Storage units (elevated tanks)
•
Oil and gas industries
- Compressor, pressure reduction, transfer, block valve, and
metering stations in gas networks
- Pumping and slide valve stations in oil pipelines
- Automation on the wellhead of gas and oil wells
- Stations for the injection of water or CO
2
in gas or oil fields
•
Energy management, environmental protection, and transpor-
tation
- Equipment for power generation and distribution
- District heating
- Traffic control systems
- Tunnels
- Railway stations
- Lighthouses
- Environmental monitoring equipment
- Weather stations
■
Design
The telecontrol center for the outstations (RTU) is integrated
into the process control of the SIMATIC PCS 7 process control
system in the form of an operator station in single station or
server design (also redundant as option). No additional automa-
tion system for conditioning and connecting telecontrol-specific
data need be planned in the SIMATIC PCS 7 system. With large
quantity frameworks, a PCS 7 TeleControl operator station
(single station/server) is preferably responsible only for the tele-
control mode (dedicated). With small quantity frameworks, a
server or a single station can also control SIMATIC PCS 7 auto-
mation systems in central plant areas in addition to the RTUs
(dual-channel mode).
To enable engineering of the PCS 7 TeleControl operator station
(single station/server), the functions of the engineering station
of the SIMATIC PCS 7 process control system are expanded
by DBA technology (Data Base Automation) and the SIMATIC
PCS 7 TeleControl block library.
For communication with the RTUs, SIMATIC PCS 7 TeleControl
uses the telecontrol protocols SINAUT ST7, DNP3 and
Modbus RTU (via serial as well as TCP/IP communication
connections) and also IEC 60870-5-101 (serial) and
IEC 60870-5-104 (Ethernet TCP/IP).
With serial RTU interfacing, the telecontrol connection can
be implemented cost-effectively at the control center end
(PCS 7 TeleControl OS as single station or server) using the
following components:
•
SINAUT TIM communication modules
(SINAUT ST7 telecontrol protocol)
•
TCP/IP-to-serial converter
e.g. devices from the companies MOXA or Lantronix
(telecontrol protocols DNP3, Modbus RTU, IEC 60870-5)
Remote stations can be connected either directly via Ethernet
TCP/IP or via TCP/IP WAN routers to the SIMATIC PCS 7 plant
bus (telecontrol protocols SINAUT ST7, DNP3, Modbus RTU,
IEC 60870-5-104). When using the SINAUT ST7 telecontrol
protocol, the SINAUT TIM communication module can be used
in addition to the TCP/IP WAN router or as an alternative.
© Siemens AG 2014
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 25 - 26 - 27 - 28 - 29 - 30 - 31 - 32 - 33 - 34 - 35 - 36 - 37 - 38 - 39 - 40 - 41 - 42 - 43 - 44 - 45 - 46 - 47 - 48 - 49 - 50 - 51 - 52 - 53 - 54 - 55 - 56 - 57 - 58 - 59 - 60 - 61 - 62 - 63 - 64 - 65 - 66 - 67 - 68 - 69 - 70 - 71 - 72 - 73 - 74 - 75 - 76 - 77 - 78 - 79 - 80 - 81 - 82 - 83 - 84 - 85 - 86 - 87 - 88 - 89 - 90 - 91 - 92 - 93 - 94 - 95 - 96 - 97 - 98 - 99 - 100 - 101 - 102 - 103 - 104 - 105 - 106 - 107 - 108 - 109 - 110 - 111 - 112 - 113 - 114 - 115 - 116 - 117 - 118 - 119 - 120 - 121 - 122 - 123 - 124 - 125 - 126 - 127 - 128 - 129 - 130 - 131 - 132 - 133 - 134 - 135 - 136 - 137 - 138 - 139 - 140 - 141 - 142 - 143 - 144 - 145 - 146 - 147 - 148 - 149 - 150 - 151 - 152 - 153 - 154 - 155 - 156 - 157 - 158 - 159 - 160 - 161 - 162 - 163 - 164 - 165 - 166 - 167 - 168 - 169 - 170 - 171 - 172 - 173 - 174 - 175 - 176 - 177 - 178 - 179 - 180 - 181 - 182 - 183 - 184 - 185 - 186 - 187 - 188 - 189 - 190 - 191 - 192 - 193 - 194 - 195 - 196 - 197 - 198 - 199 - 200 - 201 - 202

Ask for a free quotation – We are at your disposal

Call us at +39 080.5367090 or send an email to info@tecnicaindustriale.com