SIEMENS
9/25
Siemens MD 50.1 · 2015
Motor integrated frequency inverter SINAMICS G110M
0.37 kW to 4 kW
Available motor/inverter combinations
9
■
Overview
The available motor/inverter combinations that are integrated in
the motor as standard are listed in the tables below.
Due to the specific properties of SINAMICS G110M, the following
restrictions apply to the options that can be ordered with the
motors:
•
The inverter and the manual release lever of the brake cannot
be mounted in the same position
•
Standby heating is not possible for the motor
•
Terminal box position 4 (i.e. the inverter is directed downwards
in installation position M1) on request
4-pole, 1 500 rpm at 50 Hz power
1)
4-pole, 2 610 rpm at 87 Hz power
1)
1)
Other motor/inverter combinations on request.
Size
Motor
P
50Hz
Power Module
Frame Size A (FSA)
Frame Size B (FSB)
kW
0.37
0.75
1.1
1.5
2.2
3
4
Motors with Standard Efficiency IE1
71
LA71MG4
0.25
On request
LA71MH4
0.37
✓
Motors with High Efficiency IE2
80
LE80MD4E
0.55
✓
LE80MH4E
0.75
✓
✓
90
LE90SG4E
1.1
✓
✓
LE90LH4E
1.5
✓
✓
100
LE100LE4E
2.2
✓
✓
LE100LK4E
3
✓
✓
112
LE112ME4E
4
✓
Size
Motor
P
87Hz
Power Module
Frame Size A (FSA)
Frame Size B (FSB)
kW
0.37
0.75
1.1
1.5
2.2
3
4
Motors with Standard Efficiency IE1
71
LA71MH4
0.65
✓
Motors with High Efficiency IE2
80
LE80MD4E
0.95
✓
LE80MH4E
1.30
✓
90
LE90SG4E
1.90
✓
LE90LH4E
2.60
✓
100
LE100LE4E
3.60
✓
© Siemens AG 2015