9/19
Siemens MD 50.1 · 2015
Motor integrated frequency inverter SINAMICS G110M
0.37 kW to 4 kW
PM240M Power Modules
9
■
Technical specifications
(continued)
1)
The rated output current
I
rated
is based on the duty cycle for high overload (HO).
2)
Typical values. Additional information can be found on the Internet at
3)
The input current depends on the motor load and line impedance. The input currents apply for load at rated power for a line impedance corresponding
to
u
K
= 1 %.
Line voltage
380 … 480 V 3 AC
PM240M Power Modules
Rated output current
I
rated
1)
A
1.3
2.2
3.1
4.1
Maximum output current
I
max
A
2.6
4.4
6.2
8.2
Rated power
kW
0.37
0.75
1.1
1.5
Rated pulse frequency
kHz
4
4
4
4
Efficiency
η
%
96.8
98.1
98.2
97.3
Power loss
2)
at rated output current
kW
0.025
0.032
0.041
0.052
Cooling air requirement
m
3
/s
0.0048
0.0048
0.0048
0.0048
Sound pressure level
L
pA
(1 m)
dB
–
–
–
–
Rated input current
3)
A
1.3
2
2.8
3.6
Line supply connection
U1/L1, V1/L2, W1/L3, PE
• Conductor cross-section,
recommended
mm
2
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
PE connection
(external connection)
• Conductor cross-section
(recommended)
mm
2
10
10
10
10
Motor connection U2, V2, W2, PE,
motor brake, temperature sensor
• Conductor cross-section
mm
2
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
1 ... 2.5
18 ... 14 AWG
Motor cable length, max.
Shielded
m
–
–
–
–
Degree of protection
IP66
IP66
IP66
IP66
Dimensions
• Width
mm
161
161
161
161
• Height
mm
135
135
135
135
• Depth
mm
270
270
270
270
Frame size
FSA
FSA
FSA
FSA
Weight, approx.
kg
2.1
2.1
2.1
2.1
© Siemens AG 2015