SIEMENS
2/14
Siemens D 15.1 · 2017
SINAMICS PERFECT HARMONY GH180
Air-Cooled Drives
Options
2
■
Options
The following tables show an overview of the options and their availability for the SINAMICS PERFECT HARMONY GH180 drive series
(details
see chapter 4, description of options
).
1)
Option
B19
is available exclusively for drives with article No. 6SR4... and
motor voltages of 6.0 kV and 6.6 kV.
2)
Options "ProToPS"
U10
and "Cell bypass"
U11
are mutually exclusive.
3)
The option is included in the option
U02
.
4)
Options "control and display instruments in the door"
K31
to
K34
are
mutually exclusive. Select one of them.
K31
is the preset value.
5)
With options
K68,
K69
and
K79
the power source is defined. These
options are mutually exclusive. Select one of them.
K69
is the preset value.
6)
Options "control of auxiliaries"
N30
to
N33
as well as
N35
to
N38
are mutually
exclusive.
Option text
Order
code
Article No.
6SR4...
6SR3...
Shorter delivery time
Express Line
1)
B19
✓
–
Reduced number of cells
Drive with reduced number of cells
N80
✓
–
Availability
ProToPS
2)
U10
✓
✓
Cell bypass
2)
U11
✓
✓
Redundant single cell
U12
✓
✓
Redundant rank of cells
U13
✓
✓
Redundant blower
M61
✓
✓
Certifications
CE certificate
U02
✓
✓
EAC certificate
U04
✓
✓
Cooling type
Drive prepared for connection to an external air
discharge system, front connection
M64
✓
✓
Drive prepared for connection to an external air
discharge system, rear connection
M68
✓
✓
Protection functions
Make-proof grounding switch at drive input
N44
✓
✓
Make-proof grounding switch at drive output
N45
✓
✓
Mechanical door interlock – Castell
M10
✓
✓
Electrical door interlocks
3)
M12
✓
✓
Serial communication
Modbus interface, network 1
G22
✓
✓
DeviceNet profile 12 interface, network 1
G23
✓
✓
Control Net interface, network 1
G26
✓
✓
Modbus Ethernet interface, network 1
G28
✓
✓
Additional Modbus interface
G32
✓
✓
Additional Modbus Ethernet interface
G38
✓
✓
DeviceNet profile 12 interface, network 2
G43
✓
✓
Control Net interface, network 2
G46
✓
✓
PROFIBUS DP interface, network 1
G91
✓
✓
PROFIBUS DP interface, network 2
G93
✓
✓
Port connectors
Ethernet port connector mounted on the door
G47
✓
✓
Functional options
Engineering and parameter configuration
for ESP applications
B09
✓
✓
Drive adapted to ZLU requirements
(on request)
B10
✓
✓
Speed sensing module
(requires a speed encoder)
K50
✓
✓
Output reactor (only for synch.)
L09
✓
✓
Bidirectional synchronized bypass operation
L29
✓
✓
Control and display instruments in the door
4)
Indicator lights
K20
✓
✓
3 display instruments in the cabinet door
K21
✓
✓
Pushbutton kit
K29
✓
✓
Off/Local/Remote selector
K31
✓
✓
Off/Hand/Auto selector
K32
✓
✓
Keyed Off/Local/Remote selector
K33
✓
✓
Keyed Off/Hand/Auto selector
K34
✓
✓
Control voltage supply
5)
Connection for control voltage 220/230 V AC
by customer
K68
✓
✓
Control voltage internal
K69
✓
✓
Connection for control voltage 120 V AC by
customer
K79
✓
✓
Control voltage 24 V DC for digital inputs/out-
puts
K73
✓
✓
Control of auxiliaries
6)
Controlled outgoing feeder for motor blowers
N30 to
N33
✓
✓
Controlled outgoing feeder for anti-condensa-
tion heating
N35 to
N38
✓
✓
Power supply for external devices
24 V DC/2.5 A
N75
✓
✓
Temperature detection and evaluation
2 x 2 thermistor protection relays
L81
✓
✓
3 x 2 thermistor protection relays
L82
✓
✓
2 Pt100 evaluation units with 3 inputs each
L91
✓
✓
Pt100 evaluation unit with 6 inputs and
2 analog outputs
L93
✓
✓
Pt100 evaluation unit with 6 inputs for ex-proof
motors and 6 analog outputs
L95
✓
✓
Option text
Order
code
Article No.
6SR4...
6SR3...
© Siemens AG 2017