SIEMENS
3/2
Siemens D 15.1 · 2017
Technical Data
General technical data
3
■
Technical data
General technical data
Power semiconductors
Diodes, IGBTs
Line-side rectifier
18 to 36 pulse diode rectifiers
Motor-side inverter
Multi-level drive (PWM) with IGBT power modules
Closed-loop control
Sensorless closed-loop control
Drive quadrants
2
Potential separation (power section/
open- and closed-loop control)
Fiber-optic cable
Efficiency
Up to 96 % including transformer, across whole power range
Conformance
IEC, IEEE, ANSI, NEMA, CSA, CE and UL
Paint finish
RAL 7035
Degree of protection
1)
• IP21 (standard)
• IP42 (option)
Air cooling
Forced-air cooling
Altitude
2)
m
0 ... 1000 without derating
ft
0 ... 3300 without derating
Permissible ambient temperature
Refer to table below
Storage
Transport
Operation
Climatic ambient conditions
Ambient temperature
°C
+5 ... +40
-25 ... +60
+5 ... +40
3)
Relative air humidity
<
95 %
(only slight condensation permit-
ted; drive must be completely dry
before commissioning)
<
95 %
(only slight condensation permit-
ted; drive must be completely dry
before commissioning)
< 95 %
(condensation not permitted)
Other climatic conditions in
accordance with class
1K3, 1Z2 in acc. with
IEC 60721-3-1
2K2 in acc. with IEC 60721-3-2
3K3 in acc. with IEC 60721-3-3
Degree of pollution
2
without conductive pollution
in acc. with IEC 61800-5
2
without conductive pollution
in acc. with IEC 61800-5
2
without conductive pollution
in acc. with IEC 61800-5
Mechanical ambient conditions
Stationary vibration,
sinusoidal
• Displacement
mm
1.5 (2 ... 9 Hz)
3.5 (2 ... 9 Hz)
0.3 (2 ... 9 Hz)
• Acceleration
m/s
2
5 (9 ... 200 Hz)
10 (9 ... 200 Hz)
1 (9 ... 200 Hz)
m/s
2
15 (200 to 500 Hz)
Other mechanical conditions in
accordance with class
1M2 in acc. with
IEC 60721-3-1
2M2 in acc. with
IEC 60721-3-2
3M1 in acc. with
IEC 60721-3-3
Other ambient conditions
Biological ambient conditions in
accordance with class
1B1 in acc. with
IEC 60721-3-1
2B1 in acc. with
IEC 60721-3-2
3B1 in acc. with
IEC 60721-3-3
Chemically active substances in
accordance with class
1C1 in acc. with
IEC 60721-3-1
2C1 in acc. with
IEC 60721-3-2
3C1 in acc. with
IEC 60721-3-3
Mechanically active substances
in accordance with class
1S1 in acc. with
IEC 60721-3-1
2S1 in acc. with
IEC 60721-3-2
3S1 (standard) in acc. with
IEC 60721-3-3
1)
Acc. to IEC 60529.
2)
For altitudes above 1000 m (3300 ft), please contact the factory or your local Siemens sales representative.
3)
For ambient temperatures above 40 °C, please contact the factory or your local Siemens sales representative.
© Siemens AG 2017