Description of Options
Description of options
4
■
Options
(continued)
F03 to F97
Drive acceptance tests, witnessed
Mutually exclusive options
F03
to
F97
G22 to G93
Serial communication
Mutually exclusive options
G22
to
G93
Various serial communication interfaces can be optionally
selected (no more than two total):
Number of Anybus modules required for network implementa-
tion using NXGpro
G47
Ethernet port connector (mounted on the door)
For drives manufactured in Nuremberg, Germany, the Ethernet
port connector is included in the standard scope of delivery.
Option
G47
must be ordered.
Drive acceptance tests, wit-
nessed
Code
F03
F73
F77
F79
F97
Visual acceptance of the drive
F03
–
✓
✓
✓
Functional acceptance of the drive
with inductive load
F73
–
✓
✓
✓
Acceptance test of the insulation of
the drive
F77
✓
✓
✓
✓
Interface check with customer
equipment (5 hours, on request)
F79
✓
✓
✓
✓
Customer-specific acceptance
F97
✓
✓
✓
✓
✓
Options can be combined.
–
Options are mutually exclusive.
Option
Description
F03
Visual acceptance of the drive
Open doors/panels; inspection of drive before shipping
F73
Functional acceptance of the drive with inductive load
Visual acceptance; functional test with inductive load, cooling
system test.
Option
F73
includes option
F03
(visual acceptance).
F77
Acceptance test of the insulation of the drive
The following is included in the scope of the acceptance tests:
• High-voltage test
• The insulation resistance is measured
F79
Interface check with customer equipment (5 hours, on
request)
For details, please contact the factory or your local Siemens
sales representative.
F97
Customer-specific acceptance
For details, please contact the factory or your local Siemens
sales representative.
Serial
communication
Code
G22
G23
G26
G28
G91
G32
G38
G43
G46
G93
Modbus interface
G22
–
–
–
–
✓
✓
✓
✓
✓
DeviceNet profile 12
interface
G23
–
–
–
–
✓
✓
✓
✓
✓
Control Net interface
G26
–
–
–
–
✓
✓
✓
✓
✓
Modbus Ethernet inter-
face
G28
–
–
–
–
✓
✓
✓
✓
✓
PROFIBUS DP interface
G91
–
–
–
–
✓
✓
✓
✓
✓
Additional Modbus
interface
G32
✓
✓
✓
✓
✓
–
–
–
–
Additional Modbus
Ethernet interface
G38
✓
✓
✓
✓
✓
–
–
–
–
DeviceNet profile 12
interface, network 2
G43
✓
✓
✓
✓
✓
–
–
–
–
Control Net interface,
network 2
G46
✓
✓
✓
✓
✓
–
–
–
–
PROFIBUS DP
interface, network 2
G93
✓
✓
✓
✓
✓
–
–
–
–
✓
Options can be combined.
–
Options are mutually exclusive.
Option
Description
G22
Modbus interface
Note:
If a second Modbus interface is required, select options
G22
and
G32
.
G23
DeviceNet profile 12 interface
Note:
If a second DeviceNet interface is required, select
options
G23
and
G43
.
G26
Control Net interface
Note:
If a second Control Net interface is required, select
options
G26
and
G46
.
G28
Modbus Ethernet interface
Note:
If a second Modbus Ethernet interface is required, select
options
G28
and
G38
.
G32
Additional Modbus interface
G38
Additional Modbus Ethernet interface
G43
DeviceNet profile 12 interface, network 2
G46
Control Net interface, network 2
G91
PROFIBUS DP interface
Note:
If a second PROFIBUS DP interface is required, select
options
G91
and
G93
.
G93
PROFIBUS DP interface, network 2
Network 2
Network 1
Modbus
(
G32
)
Modbus Ethernet
(
G38
)
DeviceNet profile 12
(
G43
)
Control Net
(
G46
)
PROFIBUS DP
(
G93
)
Modbus
1)
(
G22
)
1
1
1
1
1
DeviceNet profile 12 (
G23
)
2
2
2
2
2
Control Net (
G26
)
2
2
2
2
2
Modbus Ethernet
2)
(
G28
)
1
1
1
1
1
PROFIBUS DP (
G91
)
2
2
2
2
2
Serial
communication
Code
G22
G23
G26
G28
G91
G32
G38
G43
G46
G93
1)
Network 1 Modbus uses the COM port on the communications board.
2)
Network 1 Modbus Ethernet uses the Ethernet port on the CPU card.
Customers must provide an additional Ethernet switch to guarantee the
functionality of both ports.