SIEMENS
3/22
Siemens D 15.1 · 2017
Technical Data
SINAMICS PERFECT HARMONY GH180, article number 6SR3...
3
■
Technical data
SINAMICS PERFECT HARMONY GH180
air-cooled drive version
6SR3102-
3.J43-5..0
6SR3102-
3.J44-0..0
6SR3102-
3.J45-0..0
6SR3102-
3.K45-0..0
6SR3102-
3.K46-0..0
Motor voltage 4.16 kV
Max. output voltage
kV
4.9
4.9
4.9
4.9
4.9
Type rating
kVA
3080
3520
3600
4400
4540
Shaft output
1)
kW
2611
2984
3056
3730
3851
hp
3500
4000
4097
5000
5162
Typical motor current
1)
A
427
488
500
610
630
Power cell current
A
500
500
500
660
660
Number of cells
12
12
12
12
12
Aluminum transformer available
Yes
Yes
On request
On request
No
Power loss of drive system
• with copper transformer
kW
< 92
< 105
< 107
< 131
< 135
• with aluminum transformer
kW
< 92
< 105
–
–
–
Efficiency
P
out
/
P
in
2)
of drive system
• with copper transformer
%
> 96.5
> 96.5
> 96.5
> 96.5
> 96.5
• with aluminum transformer
%
> 96.5
> 96.5
–
–
–
Auxiliary supply
• Single-phase w/o options
3)
kVA
< 1.5
< 1.5
< 1.5
< 1.5
< 1.5
• Single-phase w/ all options
3)
kVA
< 3
< 3
< 3
< 3
< 3
• Three-phase w/o CPT
4)
kVA
< 16
< 16
< 16
< 16
< 16
• Three-phase w/ CPT and all
options
4)
kVA
< 19
< 19
< 19
< 19
< 19
Cooling medium flow rate
m
3
/s
8.5
8.5
8.5
8.5
8.5
CFM
18000
18000
18000
18000
18000
Sound pressure level
L
pA
(1 m)
dB (A)
80
80
80
80
80
Power cabling cross-sections
• Cable cross-sections,
line-side, max. connectable per
phase
5)
AWG/MCM
(NEC, CEC)
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
mm
2
(DIN VDE)
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
• Cable cross-sections,
motor-side, max. connectable
per phase
5)
AWG/MCM
(NEC, CEC)
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
2 x 1000 MCM
mm
2
(DIN VDE)
2 x 500
2 x 500
2 x 500
2 x 500
2 x 500
• PE connection,
max. connection cross-section
at enclosure
5)
AWG/MCM
(NEC, CEC)
1000 MCM
1000 MCM
1000 MCM
1000 MCM
1000 MCM
mm
2
(DIN VDE)
500
500
500
500
500
Degree of protection
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
Drive dimensions (input cabinet, transformer cabinet and cell cabinet)
6)
• Width
mm
6270
6270
6880
6880
6880
in
247
247
271
271
271
• Height (incl. blowers)
mm
2995
2995
2995
2995
2995
in
118
118
118
118
118
• Depth
mm
1270
1270
1270
1270
1270
in
50
50
50
50
50
• Schematic drawing
7)
C
C
C
C
C
Drive weight (input cabinet, transformer cabinet and cell cabinet)
• Weight, approx.
kg
12500
12300
14500
15000
15500
lb
27500
27100
32000
33000
34000
1)
The specifications for the typical motor current and the power data in kW and hp are approximate values only; these have been calculated for operation with
induction motors and for a typical power factor cos
and motor efficiency. Both approximate values have to be adapted to the motor that is actually used.
2)
Values at 100 % of rated speed and torque; includes drive and input transformer.
3)
120/240 V AC for NXGpro control
- CPT is an option.
4)
Includes cooling blowers/pumps; data refers to the largest unit.
5)
Maximum installable size per phase.
6)
If an aluminum transformer is selected, drive dimensions may change.
7)
Please refer to page 3/21
for schematic drawing.
© Siemens AG 2017