SIEMENS
3-18
2015 Low Voltage AC Motors Selection and Pricing Guide
Main Terminal Box
Auxiliary Box
Opp. Main Box Side for
Cast Iron
J84 = Entry
from DE
J85 = Entry
from top
Entry from NDE
PTC
Thermostats
KTY84
Space Heaters
L01
J84
J85
J86
J05
J15
J25
J55
MOD
QM
QM
QM
MOD
MOD
GP100A
NA
NA
NA
NA
NA
NA
NA
NA
GP100
140-400
140-440
140-440
140-440
280-S440
280-S440
280-S440
280-S440
SD100
Std
140-S440
140-S440
140-S440
280-S440
280-S440
280-S440
280-S440
SD100 IEEE841
Std
140-S440
140-S440
140-S440
280-S440
280-S440
280-S440
280-S440
SD661
Std
180-360
180-360
180-360
280-360
280-360
280-360
280-360
RGZ(K)ESDI
Std
140-S440
140-S440
140-S440
280-S440
280-S440
280-S440
280-S440
XP100
Std
140-440
140-440
140-440
NA
NA
NA
NA
XP100 ID1
Std
140-440
140-440
140-440
NA
NA
NA
NA
SD10 MS
Std
140-440
140-440
140-440
280-440
280-440
280-440
280-440
RGZV(IL)ESD
NA
140-440
140-440
140-440
280-440
280-440
280-440
280-440
Main Terminal Box
Auxiliary Box
Opp. Main Box Side for
Auxiliary Box
to Main Box for
B1)
Condulet on Same
Side of Main Box for
Cast
iron
J84 = Entry
from DE
J85 = Entry
from top
Entry
from NDE
PTC
Thermo-
stats
KTY84
Space
Heaters
PTC
Thermo-
stats
KTY84
Space
Heaters
PTC
Thermo-
stats
KTY84
Space
Heaters
L01
J84
J85
J86
J05
J15
J25
J55
J03
J13
J23
J53
J00
J10
J20
J50
140
148
134
134
134
–
–
–
–
–
–
–
–
–
–
–
–
180
154
134
134
134
–
–
–
–
–
–
–
–
–
–
–
–
210
161
134
134
134
–
–
–
–
–
–
–
–
–
–
–
–
250
167
134
134
134
–
–
–
–
–
–
–
–
–
–
–
–
280
180
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
320
199
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
360
218
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
400
251
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
440
–
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
S449
–
134
134
134
443
443
443
443
415
415
415
415
235
235
235
235
Terminal Box
List Price
Options selection and pricing
Auxiliary Box
to Main Box for
B1)
Condulet on Same
Side of Main Box for
PTC
Thermostats
KTY84
Space
Heaters
PTC
Thermostats
KTY84
Space
Heaters
J03
J13
J23
J53
J00
J10
J20
J50
MOD
MOD
GP100A
NA
NA
NA
NA
NA
NA
NA
NA
GP100
NA
NA
NA
NA
280-440
280-440
280-440
280-440
SD100
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
SD100 IEEE841
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
280-S440
SD661
280-360
280-360
280-360
280-360
280-360
280-360
280-360
280-360
RGZ(K)ESDI
NA
NA
NA
NA
NA
NA
NA
NA
XP100
NA
NA
NA
NA
NA
NA
NA
NA
XP100 ID1
NA
NA
NA
NA
NA
NA
NA
NA
SD10 MS
280-440
280-440
280-440
280-440
280-440
280-440
280-440
280-440
RGZV(IL)ESD
280-440
280-440
280-440
280-440
NA
NA
NA
NA
B1)
GP motors: Only for motors with cast iron terminal box.
B2)
MOD if mounting with T. box on RHS, (MLFB digit 16 = 2, 5, 6, or 8).
B3)