ABB
ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 12-2007
97
2
Efficiency
Power factor
Current
Torque
Sound
Full
3/4
Full
3/4
I
N
I
S
I
0
T
N
T
S
T
max
Rotor
Motor
pressure
Output
Motor
Product
Speed
load
load
load
load
inertia
weight
level L
P
kW
type
ID
r/min
100%
75%
100% 75%
A
I
N
A
Nm
T
N
T
N
kgm
2
kg
dB(A)
HV Modular motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
3000 V - 50 Hz
1000 r/min = 6 poles
3000 V 50 Hz
500
AMA 400L6L
1024
986
95.1
95.5
0.84
0.82
120
4.5
40
4841
0.7
1.8
15.5
2780
77
560
AMA 400L6L
1025
987
95.4
95.6
0.84
0.80
135
4.9
49
5416
0.8
2.0
16.7
2880
77
630
AMA 400L6L
1026
987
95.3
95.7
0.85
0.82
150
4.7
50
6096
0.7
1.9
18.0
2960
77
710
AMA 400L6L
1027
988
95.6
95.9
0.85
0.82
169
5.2
59
6861
0.8
2.1
20.4
3150
77
800
AMA 400L6L
1028
988
95.7
96.0
0.84
0.81
192
5.3
69
7729
0.9
2.1
21.6
3250
77
900
AMA 400L6L
1029
988
95.8
96.1
0.85
0.82
213
5.2
71
8697
0.9
2.0
24.0
3440
77
1000
AMA 450L6L
1030
992
96.3
96.4
0.81
0.77
245
5.4
101
9626
0.7
2.1
37.4
4020
78
1120
AMA 450L6L
1031
991
96.3
96.6
0.86
0.84
260
5.2
81
10796
0.7
2.0
40.0
4140
78
1250
AMA 450L6L
1032
990
96.2
96.6
0.87
0.85
289
4.9
80
12059
0.7
1.9
42.3
4250
78
1400
AMA 450L6L
1033
990
96.3
96.7
0.87
0.86
322
5.0
89
13502
0.7
2.0
46.8
4490
78
1600
AMA 500L6L
1034
991
96.5
96.8
0.88
0.87
362
5.2
94
15418
0.7
1.9
65.5
5300
79
1800
AMA 500L6L
1035
992
96.6
96.9
0.88
0.86
408
5.6
113
17334
0.8
2.1
72.8
5570
79
2000
AMA 500L6L
1158
991
96.7
97.0
0.89
0.88
446
5.4
105
19271
0.8
2.0
80.2
5890
79
2250
AMA 500L6L
1159
991
96.8
97.1
0.89
0.88
502
5.5
121
21673
0.8
2.0
87.6
6190
79
750 r/min = 8 poles
3000 V 50 Hz
315
AMA 400L8L
1036
738
94.5
94.9
0.83
0.81
77
4.6
27
4075
0.9
1.8
17.5
2730
75
355
AMA 400L8L
1037
739
94.7
95.0
0.83
0.80
86
4.7
31
4585
0.8
1.9
19.0
2830
75
400
AMA 400L8L
1038
739
94.9
95.3
0.84
0.81
97
4.8
35
5166
0.9
1.9
20.4
2930
75
450
AMA 400L8L
1039
739
95.1
95.4
0.84
0.81
108
4.7
37
5814
0.8
1.8
21.8
3040
75
500
AMA 400L8L
1040
739
95.1
95.5
0.84
0.82
120
4.7
41
6460
0.9
1.8
23.3
3120
75
560
AMA 400L8L
1041
739
95.2
95.5
0.84
0.81
135
4.8
47
7233
0.9
1.8
24.7
3220
75
630
AMA 400L8L
1042
739
95.2
95.6
0.84
0.82
151
4.7
50
8139
0.9
1.8
27.5
3400
75
710
AMA 450L8L
1043
742
95.8
96.0
0.83
0.80
171
5.3
66
9137
0.8
2.1
40.7
3850
76
800
AMA 450L8L
1044
741
95.8
96.2
0.86
0.84
188
4.8
58
10310
0.7
1.8
46.1
4090
76
900
AMA 450L8L
1045
741
95.8
96.3
0.86
0.84
210
4.8
63
11597
0.7
1.8
51.5
4310
76
1000
AMA 450L8L
1046
743
96.2
96.4
0.83
0.80
240
5.7
93
12854
0.9
2.2
56.7
4550
76
1120
AMA 500L8L
1047
739
95.9
96.4
0.87
0.86
258
4.5
66
14463
0.7
1.8
75.5
5240
77
1250
AMA 500L8L
1048
741
96.2
96.6
0.87
0.86
287
4.7
76
16105
0.7
1.8
84.9
5550
77
1400
AMA 500L8L
1049
742
96.4
96.7
0.87
0.85
323
5.2
96
18015
0.8
2.0
93.7
5830
77
1600
AMA 500L8L
1160
742
96.4
96.7
0.87
0.86
367
5.0
101
20601
0.8
1.9
102.6
6130
77
Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is