SIEMENS
9/17
Siemens D 31 · 2015
9
■
Technical specifications
SINAMICS S110 servo drives
0.12 kW to 90 kW (0.16 hp to 125 hp)
PM340 Power Modules in blocksize format
1)
Rated power of a typical standard asynchronous (induction) motor at
230 V 3 AC.
2)
The input current depends on the motor load and line impedance. The
input currents apply for rated power loading (based on
I
rated
) for a line
impedance corresponding to
u
k
= 1%.
3)
Max. motor cable length 15 m (shielded) for PM340 Power Modules with
integrated line filter to maintain the limit values of EN 61800-3 Category C2.
Line voltage 200 ... 240 V 1 AC
Air-cooled PM340 Power Module in blocksize format
6SL3210-1SB11-0...
6SL3210-1SB12-3...
6SL3210-1SB14-0...
Output current
• Rated current
I
rated
A
0.9
2.3
3.9
• Base-load current
I
H
A
0.8
2
3.4
• For S6 duty (40 %)
I
S6
A
1.4
3.3
5.5
• Maximum current
I
max
A
2
4.6
7.8
Type rating
1)
Based on
I
rated
kW (hp)
0.12 (0.16)
0.37 (0.5)
0.75 (0.75)
Rated pulse frequency
kHz
4
4
4
Power loss
kW
0.06
0.075
0.11
Cooling air requirement
m
3
/s (ft
3
/s)
0.005 (0.2)
0.005 (0.2)
0.005 (0.2)
Sound pressure level
L
pA
(1 m)
dB
<45
<45
<45
24 V DC power supply
for Control Unit
A
1
1
1
Rated input current
2)
with/without line reactor
A
1.4/2.2
4/6
6.5/10
Resistance value
of the external braking resistor
Ω
≥
180
≥
180
≥
180
Cable length
to braking resistor, max.
m (ft)
15 (49)
15 (49)
15 (49)
Line supply connection
L, N
Screw-type terminals
Screw-type terminals
Screw-type terminals
• Conductor cross-section
mm
2
1 ... 2.5
1 ... 2.5
1 ... 2.5
DC link connection,
connection for braking resistor
DCP/R1, DCN, R2
Screw-type terminals
Screw-type terminals
Screw-type terminals
• Conductor cross-section
mm
2
1 ... 2.5
1 ... 2.5
1 ... 2.5
Motor connection
U2, V2, W2
Screw-type terminals
Screw-type terminals
Screw-type terminals
• Conductor cross-section
mm
2
1 ... 2.5
1 ... 2.5
1 ... 2.5
PE connection
M4 screw
M4 screw
M4 screw
Motor cable length
3)
, max.
(without external options)
• Shielded
m (ft)
50 (164)
50 (164)
50 (164)
• Unshielded
m (ft)
75 (246)
75 (246)
75 (246)
Degree of protection
IP20
IP20
IP20
Dimensions
• Width
mm (in)
73 (2.87)
73 (2.87)
73 (2.87)
• Height
mm (in)
173 (6.81)
173 (6.81)
173 (6.81)
• Depth
- PM340
mm (in)
145 (5.71)
145 (5.71)
145 (5.71)
-
PM340 with CU305 PN
mm (in)
216 (8.50)
216 (8.50)
216 (8.50)
-
PM340 with CU305 DP/CAN
mm (in)
200 (7.87)
200 (7.87)
200 (7.87)
Frame size
FSA
FSA
FSA
Weight, approx.
kg (lb)
1.2 (2.65)
1.3 (2.87)
1.3 (2.87)
© Siemens AG 2014