SIEMENS
7/7
Siemens D 31 · 2015
7
SINAMICS G110D distributed inverters
0.75 kW to 7.5 kW (1 hp to 10 hp)
SINAMICS G110D distributed inverters
■
Configuration
The following electronic configuring aids and engineering tools
are available for the SINAMICS G110D distributed inverters:
Drive Technology Configurator (DT Configurator)
within CA 01
The interactive catalog CA 01 – the offline Industry mall of
Siemens on DVD-ROM – contains over 100,000 products with
approximately 5 million possible drive system product variants.
The Drive Technology Configurator (DT Configurator) has been
developed to facilitate selection of the correct motor and/or
inverter from the wide spectrum of available drives. It is inte-
grated as a selection tool in catalog CA 01.
Online DT Configurator
In addition, the DT Configurator can be used on the Internet with-
out requiring any installation. The DT Configurator can be found
in the Siemens Industry Mall at the following address:
/dt-configurator
STARTER commissioning tool
The STARTER commissioning tool allows menu-prompted
commissioning, optimization and diagnostics. Apart from the
SINAMICS drives, STARTER is also suitable for the
MICROMASTER 4 devices and for SINAMICS G110D with
STARTER V4.1.3 and higher.
You can find further information on the STARTER commissioning
tool in the section Engineering Tools.
Additional information about the STARTER commissioning tool is
also available on the Internet at
/starter
Drive ES engineering system
Drive ES is the engineering system that can be used to integrate
the communication, configuration and data management func-
tions of Siemens drive technology into the SIMATIC automation
world easily, efficiently and cost-effectively. The STEP 7 Manager
user interface provides the ideal basis for this. A variety of soft-
ware packages are available for SINAMICS- Drive ES Basic,
Drive ES SIMATIC and Drive ES PCS.
You can find further information on the Drive ES engineering
system in the section Engineering Tools.
Additional information about the Drive ES engineering system is
also available on the Internet at
/drive-es
■
Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all SINAMICS G110D distributed inverters.
General technical specifications
Mechanical specifications
Vibratory load
• Transport acc. to EN 60721-3-2
1)
Class 1M2
• Operation acc. to EN 60721-3-3
Class 3M2
Shock load
• Transport acc. to EN 60721-3-2
1)
Class 1M2
• Operation acc. to EN 60721-3-3
Class 3M2
Ambient conditions
Degree of protection
IP65/UL Type 3
Protection class
According to EN 61800-5-1
Class III (PELV)
Touch protection
According to EN 61800-5-1
Class I (with protective conductor system)
Humidity, max.
95 % at 40 °C (104 °F)
Ambient temperature
• Storage
1)
acc. to EN 60068-2-1
-40 ... +70 °C (-40 ... +158 °F)
• Transport
1)
acc. to EN 60068-2-1
-40 ... +70 °C (-40 ... +158 °F)
• Operation acc. to EN 60068-2-2
-10 ... +40 °C (14 ... +104 °F) without derating
>40 ... 55 °C (104 ... +131 °F)
see derating characteristics
Environmental class/harmful chemical substances
• Operation acc. to EN 60721-3-3
Class 3C2
Pollution degree
According to EN 61800-5-1
2
Standards
Compliance with standards
UL 508C (UL list number E121068), CE, C-Tick
CE marking, according to
Low-Voltage Directive 2006/95/EC
EMC Directive
2)
• Frame sizes FSA to FSC with integrated line filter class A
Category C2
3)
acc. to
EN 61800-3
1)
In product packaging.
2)
For further general information
see also chapter SINAMICS G120, Technical
specifications, Compliance with standards.
3)
With shielded motor cable up to 15 m.
Note
:
The EMC product standard EN 61800-3 does not apply directly to a
frequency inverter but to a PDS (Power Drive System), which comprises
the complete circuitry, motor and cables in addition to the inverter. The
frequency inverters on their own do not generally require identification
according to the EMC Directive.
© Siemens AG 2014