SIEMENS
7/5
Siemens D 31 · 2015
7
SINAMICS G110D distributed inverters
0.75 kW to 7.5 kW (1 hp to 10 hp)
SINAMICS G110D distributed inverters
■
Design
The SINAMICS G110D distributed inverters are compact fre-
quency inverters for standard drives. Each SINAMICS G110D
includes both the Control Unit as well as the Power Module in
one unit.
SINAMICS G110D with integrated maintenance switch and manual local
control with keyswitch
SINAMICS G110D features an integrated brake chopper and is
suitable for distributed drives without energy recovery capability.
If generator energy is produced then this is dissipated in the
externally connected braking resistors. The communication is
realized via the local inputs (digital and analog) or via the AS-
Interface bus integrated as standard.
SINAMICS G110D with integrated maintenance switch
The inverter is available in two versions: With and without main-
tenance switch. Thanks to the optional maintenance switch (this
cannot be retrofitted), when service is required, the inverter can
be simply disconnected from the line supply without having to
have any additional components or additional wiring costs when
configuring.
Accessories
Braking resistors
Excess energy in the DC link is dissipated in the braking resis-
tors. The braking resistors are designed for use with the
SINAMICS G110D. This has an integrated brake chopper
(electronic switch).
Intelligent Operator Panel IOP Handheld
User-friendly and powerful operator panel for commissioning
and diagnostics as well as local operator control and monitoring
of SINAMICS G110D.
Manual local control with keyswitch
Master control can be toggled between automatic mode (PLC)
and manual local mode using the manual local control. This can
also be used to switch off the inverter. Additional functions in-
clude switching over between continuous and jog mode, start-
ing the motor including direction of rotation and deactivating the
quick stop in the manual mode.
Memory card
The parameter settings for an inverter can be stored on the
SINAMICS SD card. When service is required, e.g. after the in-
verter has been replaced and the data have been downloaded
from the memory card, the drive system is immediately ready for
use again. The associated memory card holder is not included
in the scope of supply of the inverter and must be separately
ordered.
Card holder for memory card
To use the SINAMICS
SD memory card, a card holder is required
that is inserted under the blanking cover or under the manual/
automatic control operator panel on the inverter.
RS232 interface cable for communication with a PC
For controlling and commissioning an inverter directly from a PC
if the appropriate software (STARTER commissioning tool V4.1.3
and higher) has been installed.
USB interface cable for communication with a PC
For controlling and commissioning an inverter directly from a PC
if the appropriate software (STARTER commissioning tool V4.1.3
and higher) has been installed.
Adapter for mounting the SINAMICS G110D instead of a
SIRIUS M200D motor starter
Connection board kit to mount a SINAMICS G110D inverter
on the connection holes of the SIRIUS M200D motor starter
(assuming that there is enough space).
Connector kit for braking resistor
Connector kit for using or connecting different braking resistors.
UL connector kit
Special UL connector kit for UL-compatible applications.
Protection bar
Protection bar for protecting the connector against shearing due
to mechanical stress
Connecting cable
Connector sets to connect to the line supply and the outgoing
motor feeder are available as accessories as well as pre-assem-
bled motor cables for connection to the motor.
Flexible plug-in cables to transfer data between AS-Interface
participants as well as to supply the Control Unit and the Power
Module with power.
Spare Parts Kit
A Spare Parts Kit is available which comprises small parts such
as seals, caps and screws.
Replacement fan
A replacement fan is available, which comprises a pre-mounted
unit with cover, fan and screws.
© Siemens AG 2014