SIEMENS
5/50
Siemens D 31 · 2015
5
■
Technical specifications
SINAMICS G120 standard inverters
0.37 kW to 250 kW (0.5 hp to 400 hp)
Power Modules
1)
Applies to industrial control panel installations to NEC article 409 or
UL 508A.
2)
Applies to PM230 Power Modules, frame sizes FSA to FSC.
3)
Applies to all PM250 Power Modules with integrated line filter class A.
Degree of protection
IP20 (standard or push-
through)
IP20 (standard or push-
through)
IP20
IP20
Operating temperature
• Low overload
(LO)
0 ... 40 °C (32 ... 104 °F)
without derating
>40 ... 60 °C (>104 ... 140 °F)
see derating characteristics
0 ... 40 °C (32 ... 104 °F)
without derating
>40 ... 60 °C (>104 ... 140 °F)
see derating characteristics
Frame sizes FSD to FSF:
0 ... 40 °C (32 … 104 °F)
without derating
>40 ... 60 °C (>104 ... 140 °F)
see derating characteristics
Frame size FSGX:
0 ... 40 °C (32 ... 104 °F)
without derating
>40 ... 55 °C (>104 ... 131 °F)
see derating characteristics
0 ... 40 °C (32 ... 104 °F)
without derating
>40 ... 60 °C (>104 ... 140 °F)
see derating characteristics
• High overload
(HO)
0 ... 50 °C (32 ... 122 °F)
without derating
>50 ... 60 °C (>122 ... 140 °F)
see derating characteristics
0 ... 50 °C (32 ... 122 °F)
without derating
>50 ... 60 °C (>122 ... 140 °F)
see derating characteristics
Frame sizes FSD to FSF:
0 ... 50 °C (32 ... 122 °F)
without derating
>50 ... 60 °C (>122 ... 140 °F)
see derating characteristics
Frame size FSGX:
0 ... 40 °C (32 ... 104 °F)
without derating
>40 ... 55 °C (>104 ... 131 °F)
see derating characteristics
0 ... 50 °C (32 ... 122 °F)
without derating
>50 ... 60 °C (>122 ... 140 °F)
see derating characteristics
Storage temperature
-40 ... +70 °C (-40 ... +158 °F)
Relative humidity
< 95 % RH, condensation not permissible
Cooling
Power units with increased
air cooling using integrated
fans
Internal ventilation,
power units with increased
air cooling by built-in fans
Internal ventilation,
power units with increased
air cooling by built-in fans
Internal ventilation,
power units with increased
air cooling by built-in fans
Installation altitude
Up to 1000 m above sea level
without derating,
> 1000 m
see derating characteristics
Up to 1000 m above sea level
without derating,
>1000 m
see derating characteristics
Up to 1000 m above sea level
without derating,
>1000 m
see derating characteristics
Up to 1000 m above sea level
without derating,
>1000 m
see derating characteristics
Protection functions
• Undervoltage
• Overvoltage
• Overload
• Ground fault
• Short-circuit
• Stall protection
• Motor blocking protection
• Motor overtemperature
• Inverter overtemperature
• Parameter locking
Short Circuit Current Rating
(SCCR)
according to UL
1)
IP20 degree of protection:
65 kA
400 V: 65 kA
230 V: 40 kA
65 kA
FSC: 40 kA
FSD to FSF: 42 kA
Compliance with standards
UL, cUL
2)
, CE, C-Tick,
SEMI F47
UL, cUL, CE, C-Tick,
SEMI F47
UL, cUL, CE, C-Tick,
SEMI F47
UL
3)
, cUL
3)
, CE, C-Tick,
SEMI F47
CE marking
According to Low-Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC
Power Modules
PM230
PM240-2
PM240
PM250
© Siemens AG 2014