BALDOR
176
Inverter/Vector Motors & Controls
Farm Duty
Motors
Definite Purpose
Motors
Unit Handling Motors
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
AC Motor Adjustable Speed Range Capabilities
Inverter Drive, Vector Drive, V*S Master and RPMAC Motors
Inverter Drive, Vector Drive, V*S Master and RPMAC Motors exceed all requirements of NEMA MG-1 Parts 30 and 31 for AC induction motors
powered from adjustable speed inverter control. Satisfactory motor performance depends on proper drive setup.
Super-E
®
Motors
Super-E motors are Inverter-Ready and meet NEMA MG 1 Part 31.4.4.2. Super-E motors are suitable for use with inverter
drives. Motor inverter setup is unique to each speci±c application. Proper setup and wiring procedures must be closely
followed.
Application Considerations
It is necessary that motor-drive applications are commissioned by persons familiar with the operation and setup of
adjustable speed drives, applicable electrical codes and any other regulations.
Each drive must be tuned to the motor for the speci±c application. System operating parameters must be checked, including voltage at motor power leads, to insure that
motor/drive setup has been successfully completed.
Applications that are not properly setup can lead to substandard performance and failure of system components. In some installations, shaft grounding and isolated
bearings may prevent bearing ²uting and are available as an option or through Mod Express.
Reference the chart below for constant torque and variable torque capabilities for each product family. Torque performance depends upon proper drive setup.
Motors 48 body style and smaller are suitable for maximum 230V inverter operation.
Efficiency Savings
Signi±cant energy savings can be achieved when applying Inverter Ready motors such as the Baldor Super-E to centrifugal load applications (fan and centrifugal pump)
and running at reduced speed taking advantage of the af±nity laws where motor load and corresponding energy consumption is reduced by the cube of the speed.
FamIly
Enclosure
Frame SIze
Constant Torque
VarIable Torque
Comments
Super E Motors 230, 460 and 575 Volts
(2)
EM
TEFC
56-210
(1)
20:1
20:1
General Purpose Premium Ef±cient
250-320
10:1
20:1
360-400
4:1
20:1
444-449
2:1
20:1
EM
ODP
56-210
(1)
10:1
20:1
General Purpose Premium Ef±cient
250-320
5:1
20:1
360 - 449
2:1
20:1
ECP/XEX and
ECP8/841XL
(3)
TEFC
140
20:1
20:1
Severe Duty Premium Ef±cient
180-210
10:1
20:1
250-400
4:1
20:1
444-449
2:1
20:1
EWDM
TENV,TEFC
56-256
(1)
20:1
20:1
Washdown Duty Premium Ef±cient
ESS/SSE
TEFC
56-250
2:1
10:1
Stainless Steel Washdown Duty
TENV
56-140
4:1
10:1
Standard-E Motors 230/460 and 575V
(2) (4)
M (TEFC)
56-326T frames
(1)
4:1
20:1
General Purpose motors
360T - 449T
2:1
20:1
M (ODP)
56-326T frames
(1)
4:1
20:1
360T - 449T
2:1
20:1
CP/XT
145T frames
4:1
20:1
Severe Duty
180T-445T frames
2:1
20:1
447T-449T frames
2:1
20:1
WDM
56-215T frames
(1)
4:1
20:1
Washdown Duty
±nverter Duty and Vector Duty Motors 230, 460 and 575 Volts
IDCSWDM
TENV
56-140
5:1
10:1
Inverter Duty, Paint Free
IDCSWDM
TEFC
56-215
3:1
10:1
Inverter Duty, Paint Free
IDM
TEBC
143-5009
1000:1
1000:1
Inverter Duty, Blower Cooled
IDNM
TENV
143-256
1000:1
1000:1
Inverter Duty, Totally Enclosed Non-Ventilated
ZDM
TEBC
143-5009
1000:1
1000:1
Vector Duty, Blower Cooled
ZDNM
TENV
143-256
1000:1
1000:1
Vector Duty, Non-Ventilated
IDXM
TEXP
182-405
2:1
10:1
Inverter Duty, Explosion Proof
(2 families)
56-405
10:1
10:1
IDWNM
TENV
143-254
1000:1
1000:1
Inverter Duty, Washdown, Non-Ventilated
ZDWNM
TENV
143-254
1000:1
1000:1
Vector Duty, Washdown, Non-Ventilated
V*S Master Motors 230 & 460
Volts
IDNVSM
TENV
56-256
1000:1
1000:1
Inverter Duty, TENV, V*S Master
IDVSM
TEFC
182-449
1000:1
1000:1
Inverter Duty, TEFC, V*S Master
ZDNVSM
TENV
56-256
1000:1
1000:1
Vector Duty, TENV, V*S Master
ZDVSM
TEFC
182-449
1000:1
1000:1
Vector Duty, TEFC, V*S Master
ZDVSCP
TEFC-XT
143-326
1000:1
1000:1
Vector Duty, TEFC-XT, V*S Master
RPMAC Motors 230 & 460
IDRPMN
TENV
FL180-FL210
1000:1
1000:1
Inverter Duty, TENV, RPMAC
IDRPMN
TEFC, TEBC, DPG-FV
FL180-FL440
1000:1
1000:1
Inverter Duty, TEFC, TEBC, DPG-FV, RPMAC
ZDNRPM
TENV
FL180-FL210
1000:1
1000:1
Vector Duty, TENV, RPMAC
ZDRPM
TEFC, TEBC
FL180-L400
1000:1
1000:1
Vector Duty, TEFC & TEBC, RPMAC
ZDPM
TEBC
FL180 - FL440
1000:1
1000:1
Vector Duty, TEBC, PM, RPMAC
(1)
Baldor type 35M frames and larger
(2)
For greater speed range capabilities, please select an Inverter Duty
®
, Vector Duty
®
, V*S Master or RPM AC type motor, or contact your local Baldor Sales Office for a custom motor design.
(3)
Stock IEEE-841 motors include Division 2 labeling as standard. These motors will require a nameplate change through Mod Express to add inverter duty markings to the motors.
(4)
Standard-E EPAct efficient motors are suitable for use in adjustable speed applications per NEMA MG 1 Part 30.