SIEMENS
3/18
Siemens D 15.1 · 2017
Technical Data
SINAMICS PERFECT HARMONY GH180, article number 6SR4...
3
■
Technical data
(continued)
SINAMICS PERFECT HARMONY GH180
air-cooled drive version
6SR4102-
2.C41-5..0
6SR4102-
2.D41-5..0
6SR4102-
2.D41-7..0
6SR4102-
2.D42-0..0
6SR4102-
2.E42-0..0
Motor voltage 6.6 kV
Max. output voltage
kV
6.6
6.6
6.6
6.6
6.6
Type rating
kVA
1140
1350
1580
1600
1760
Shaft output
1)
kW
946
1119
1306
1324
1492
hp
1268
1500
1750
1775
2000
Typical motor current
1)
A
100
118
138
140
154
Power cell current
A
100
140
140
140
200
Number of cells
15
15
15
15
15
Aluminum transformer available
Yes
Yes
Yes
Yes
Yes
Power loss of drive system
• with copper transformer
kW
< 34
< 40
< 46
< 47
< 53
• with aluminum transformer
kW
< 38
< 45
< 53
< 53
< 60
Efficiency
P
out
/
P
in
2)
of drive system
• with copper transformer
%
96.5
96.5
96.5
96.5
96.5
• with aluminum transformer
%
96
96
96
96
96
Auxiliary supply
• Single-phase w/o options
3)
kVA
< 1.5
< 1.5
< 1.5
< 1.5
< 1.5
• Single-phase w/ all options
3)
kVA
< 3
< 3
< 3
< 3
< 3
• Three-phase w/o CPT
4)
kVA
< 8
< 8
< 8
< 8
< 8
• Three-phase w/ CPT and all
options
4)
kVA
< 11
< 11
< 11
< 11
< 11
Cooling medium flow rate
m
3
/s
5
5
5
5
5.6
CFM
10600
10600
10600
10600
11900
Sound pressure level
L
pA
(1 m)
dB (A)
80
80
80
80
78
Power cabling cross-sections
• Cable cross-sections,
line-side, max. connectable per
phase
5)
AWG/MCM
(NEC, CEC)
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
mm
2
(DIN VDE)
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
• Cable cross-sections,
motor-side, max. connectable
per phase
5)
AWG/MCM
(NEC, CEC)
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
2 x 500 MCM
mm
2
(DIN VDE)
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
• PE connection,
max. connection cross-section
at enclosure
5)
AWG/MCM
(NEC, CEC)
2/0 AWG
2/0 AWG
2/0 AWG
2/0 AWG
2/0 AWG
mm
2
(DIN VDE)
70
70
70
70
70
Degree of protection
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
NEMA1/IP21
Drive dimensions (transformer cabinet and cell cabinet)
• Width
mm
4165
4165
4165
4165
4165
in
164
164
164
164
164
• Height (incl. blowers)
mm
2990
2990
2990
2990
2990
in
117.5
117.5
117.5
117.5
117.5
• Depth
mm
1250
1250
1250
1250
1250
in
49
49
49
49
49
• Schematic drawing
6)
B
B
B
B
B
Drive weight (transformer cabinet and cell cabinet)
• Weight, approx.
kg
6000
6000
6600
7000
7000
lb
13230
13230
14550
15430
15430
1)
The specifications for the typical motor current and the power data in kW and hp are approximate values only; these have been calculated for operation with
induction motors and for a typical power factor cos
and motor efficiency. Both approximate values have to be adapted to the motor that is actually used.
2)
Values at 100 % of rated speed and torque; includes drive and input transformer.
3)
120/240 V AC for NXGpro control
- 6SR4... drives derive single-phase control power from a built-in CPT as standard.
- For 6SR4... drives, customers can directly connect single-phase control power as an option (
K68
).
- CPT is an option in other systems.
4)
Includes cooling blowers/pumps; data refers to the largest unit.
5)
Maximum installable size per phase.
6)
Please refer to page 3/3
for schematic drawings.
© Siemens AG 2017