SIEMENS
9/7
Siemens D 31 · 2015
9
SINAMICS S110 servo drives
0.12 kW to 90 kW (0.16 hp to 125 hp)
SINAMICS S110 servo drives
■
Technical specifications
Unless specified otherwise, the following technical specifications are valid for all the following components of the
SINAMICS S110 drive system.
1)
In transport packaging.
Electronics power supply
24 V DC -15 %/+20 %
Vibratory load
• Transport
1)
acc. to EN 60721-3-2
-
Control Units and Power Modules
Class 2M3
• Operation
Test values acc. to EN 60068-2-6
Test Fc
10 ... 58 Hz: Constant deflection 0.075 mm
58 ... 150 Hz: Constant acceleration = 9.81 m/s
2
(1 ×
g
)
Shock stressing
• Transport
1)
acc. to EN 60721-3-2
-
Control Units and Power Modules
Class 2M3
• Operation
Test values acc. to EN 60068-2-27
Test Ea
-
Power Modules frame sizes FSA and FSB
147 m/s
2
(15 ×
g
)/11 ms
-
Power Modules frame sizes FSC to FSF
- 49 m/s
2
(5 ×
g
)/30 ms
Ambient conditions
• Protection class according to EN 61800-5-1
Class I (with protective conductor system) and Class III (PELV)
• Touch protection
DIN VDE 0106 Part 100 and BGV A 3 when used properly
• Type of cooling
Internal ventilator, power units with increased air cooling by built-in fans
Permissible ambient/coolant temperature (air) during operation
• Power Modules
0 ... 40 °C (32 ... 104 °F) without derating,
> 40 ... 55 °C (>104 ... 131 °F), see derating characteristics
• Control Units, supplementary system components, DC link components and
Sensor Modules
0 … 55 °C (32 … 131 °F)
up to 2000 m (6562 ft) above sea level
Climatic ambient conditions
• Storage
1)
acc. to EN 60721-3-1
Class 1K4
Temperature -25 ... +70 °C (-13 ... 158 °F)
• Transport
1)
acc. to EN 60721-3-2
Class 2K4
Temperature -40 … +70 °C (-40 ... 158 °F)
Max. air humidity 95% at 40 °C (104 °F)
• Operation acc. to EN 60721-3-3
Class 3K3
Temperature 0 ... 55 °C (32 ... 131 °F)
Condensation, splashwater and ice formation are not permitted
(EN 60204, Part 1)
Environmental class/harmful chemical substances
• Storage
1)
acc. to EN 60721-3-1
Class 1C2
• Transport
1)
acc. to EN 60721-3-2
Class 2C2
• Operation acc. to EN 60721-3-3
Class 3C2
Organic/biological influences
• Storage
1)
acc. to EN 60721-3-1
Class 1B1
• Transport
1)
acc. to EN 60721-3-2
Class 2B1
• Operation acc. to EN 60721-3-3
Class 3B1
Degree of pollution
According to EN 61800-5-1
2
© Siemens AG 2014