SIEMENS
3-19
2015 Low Voltage AC Motors Selection and Pricing Guide
Condulet Opposite
to Main Box Side for
B1)
PTC
Thermostats
KTY84
Space Heaters
PTC (EX)
Thermostats (EX)
KTY84 (EX)
Space Heaters
(EX)
J04
J14
J24
J54
J06
J16
J26
J56
MOD
MOD
GP100A
NA
NA
NA
NA
NA
NA
NA
NA
GP100
280-440
280-440
280-440
280-440
NA
NA
NA
NA
SD100
280-440
280-440
280-440
280-440
NA
NA
NA
NA
SD100 IEEE841
280-440
280-440
280-440
280-440
NA
NA
NA
NA
SD661
280-360
280-360
280-360
280-360
NA
NA
NA
NA
RGZ(K)ESDI
NA
NA
NA
NA
NA
NA
NA
NA
XP100
NA
NA
NA
NA
140-440
140-440
140-440
140-440
XP100 ID1
NA
NA
NA
NA
140-440
–
140-440
140-440
SD10 MS
280-440
280-440
280-440
280-440
NA
NA
NA
NA
RGZV(IL)ESD
280-440
280-440
280-440
280-440
NA
NA
NA
NA
Condulet Opposite
to Main Box Side for
B1)
Condulet
to Main Box for
Terminals
PTC
Thermo-
stats
KTY84
Space
Heaters
PTC
(EX)
Thermo-
stats
(EX)
KTY84
(EX)
Space
Heaters
(EX)
PTC
Thermo-
stats
KTY84
Space
Heaters
Burndy
Hydent
Termi-
nal
Block
Sealed
Leads
Special
Cable
Length
J04
J14
J24
J54
J06
J16
J26
J56
J02
J12
J22
J52
K80
K83
K89
Y85
140
–
–
–
–
560
560
560
560
251
251
251
251
171
228
150
228
180
–
–
–
–
560
560
560
560
251
251
251
251
171
228
150
228
210
–
–
–
–
560
560
560
560
251
251
251
251
171
228
150
228
250
–
–
–
–
560
560
560
560
251
251
251
251
171
342
150
228
280
235
235
235
235
560
560
560
560
251
251
251
251
171
342
150
228
320
235
235
235
235
560
560
560
560
251
251
251
251
171
518
150
228
360
235
235
235
235
560
560
560
560
251
251
251
251
171
518
150
304
400
235
235
235
235
560
560
560
560
251
251
251
251
171
–
200
304
440
235
235
235
235
560
560
560
560
251
251
251
251
171
–
200
304
S449
–
–
–
–
–
–
–
–
251
251
251
251
171
–
200
304
Condulet to Main Box for
Terminals
PTC
Thermostats
KTY84
Space Heaters
Burndy Hydent
YA Type
Terminal Block
Sealed Leads
B3
)
Special Cable
Length
J02
J12
J22
J52
K80
K83
K89
Y85
QM, MOD
(RHS T. Box)
B2)
QM
QM
MOD
QM
GP100A
NA
NA
NA
NA
140-250
NA
NA
NA
GP100
NA
NA
NA
NA
140-440
140-360
140-440
140-440
SD100
140-S440
140-S440
140-S440
140-S440
140-S440
140-360
140-440
140-S440
SD100 IEEE841
140-S440
140-S440
140-S440
140-S440
140-S440
140-360
140-440
140-S440
SD661
180-360
180-360
180-360
180-360
180-360
180-360
180-360
180-360
RGZ(K)ESDI
140-S440
140-S440
140-S440
140-S440
140-S440
140-360
140-S440
140-S440
XP100
NA
NA
NA
NA
140-440
NA
NA
NA
XP100 ID1
NA
NA
NA
NA
140-440
NA
NA
NA
SD10 MS
140-440
140-440
140-440
140-440
140-440
140-360
140-440
140-440
RGZV(IL)ESD
140-440
140-440
140-440
140-440
140-440
140-360
140-440
140-440
Terminal Box (cont’d)
List Price
Options selection and pricing
B1)
GP motors: Only for motors with cast iron terminal box.
B2)
MOD if mounting with T. box on RHS, (MLFB digit 16 = 2, 5, 6, or 8).
B3)
Limited to three leads.
Introduction
General
PurposeMotors
Hazardous
Duty Motors
Definite
Purpose Motors
Special
Features Detail
Options Selection
and Pricing
Typical
Performance Data
General
Dimensions
Severe
Duty Motors
Part Number
Index