SIEMENS
6/19
Siemens MD 50.8 · 2017
Motor options
Mechanical design
Motor plug
6
■
HAN Q8 motor plug
The motor plug is available for motor frame sizes 63 to 132 and
can be used for line voltages
500 V as well as rated currents
16 A. The jumpers are connected to the terminal board at the
factory depending on the selected circuit or voltage.
Technical specifications
Fig. 6/21
HAN Q8 motor plug with pin assignments for motor frame sizes 63 and 71
Fig. 6/22
HAN Q8 motor plug with pin assignments for motor frame sizes 80 to 132
Connection assignment
Number of contacts
8 +
e
Max. voltage
500 V (pollution degree 3)
Max. current load
per PIN
16 A
Specifications
CE, cUL-Rus
Degree of protection
(interlocked)
IP65
Order code:
HAN Q8 motor plug (1 bracket) EMC
N12
PIN
1
2
3
4
5
6
7
8
PE
Connection
U
-
W
Brake
Temperature-
dependent
motor protection
Brake
V
Temperature-
dependent
motor protection
Protective
conductor
1
3
4
5
6
8
7
G_D087_XX_00294
1
4
6
3
5
8
7
G_D087_XX_00295
© Siemens AG 2017