SIEMENS
6/16
Siemens MD 50.8 · 2017
Motor options
Mechanical design
Motor plug
6
■
Overview
The motor plug is supplied ready for use, and replaces the
terminal box with terminal board.
Motor plugs are also available in an EMC design. A counterplug
can also be provided.
In the basic design, the motor plug connection is in position B,
see page 6/11
. The dimensions depend on the motor frame size.
Particularly in cases where a brake with a manual release lever
is used in the direction of the non-drive end (NDE), a check must
be made to ensure that the motor plug does not collide with the
manual release lever in the direction of the drive end (DE).
The main advantages of a motor plug over a terminal box with
terminals are as follows:
•
Peripheral equipment can be quickly installed
•
Reduction of installation and repair times for end users
•
No wiring errors as a result of the plug system
•
Replacement of a geared motor without having to make any
intervention in the electronics
The winding connections and, optionally, the power supply for
the brake and the signal cables for the temperature sensors are
connected in the plug housing.
■
HAN 10E motor plug
The motor plug is compatible with the products from the
ECOFAST field device system. It is available for motor frame
sizes 63 to 132 and can be used for line voltages at the motor
plug
500 V and rated currents
16 A.
The motor plug can be used in the standard temperature range
from -20 up to +40 °C. A special design is required for higher
temperatures.
The motor connection (star or delta connection) is selected by
the customer in the form of the counterplug used.
Technical specifications
Fig. 6/16
HAN 10 E motor plug with pin assignments
Connection assignment
Number of contacts
10 +
e
Max. voltage
500 V
Max. current load
per PIN
16 A
Specifications
CE, cUL-Rus
Degree of protection
IP65
Order code:
HAN 10E motor plug (2 brackets)
N00
HAN 10E motor plug (2 brackets) EMC
N01
HAN 10E motor plug (1 bracket)
N04
HAN 10E motor plug (1 bracket) EMC
N06
HAN 10E counterplug
N18
6
7
8
9
10
1
2
3
4
5
G_D087_XX_00296
PIN
1
2
3
4
5
6
7
8
9
10
PE
Connection
U1
V1
W1
Brake
Brake
W2
U2
V2
Temperature-dependent
winding protection
Protective
conductor
© Siemens AG 2017