SIEMENS
4/24
Siemens CR 1 · 2015
4
■
Function
(continued)
SIMOCRANE CMS Crane Management System
SIMOCRANE CMS Lean and CMS Basic
Option packages
CMS Basic
–
Fast Trace function with SIPLUS CMS
An important source of information in the event of a fault is the
signal profile of: Speed, Torque, Current, Voltage, this in combi-
nation with a selection of important digital signals such as: Limit
switches, Commands, etc.
Example of screen in X-Tools for Fast Trace function
Most of these are dynamic variables. If an error occurs, the sys-
tem plots the signal profile for a predefined number of signals
and saves them for a period before and after the error.
SIPLUS CMS with X-Tool software used for this application is a
high-performance software package that is well-proven in other
sectors. As well as recording trace data, the "X-Tools" program
included in the scope of delivery offers high-performance tools
for data analysis and continuous monitoring of operating para-
meters (Condition Monitoring). This component is integrated into
the SIMOCRANE CMS user interface in such a manner that va-
lues stored in the context of an error message can be retrieved
as easily as possible. The maintenance technician requires no
special training for this tool.
Trace display in WinCC picture
Configuration of using Fast Trace
IO link
SIPLUS HW
G_CR01_EN_00369
SIPLUS HW
SIPLUS HW
Microbox IPC 427
X-Tools server
SIMOCRANE CMS
SIPLUS
SW Node
SIPLUS
SW Node
PROFINET
PROFIBUS
© Siemens AG 2015