SIEMENS
4/15
Siemens CR 1 · 2015
4
■
Function
(continued)
SIMOCRANE CMS Crane Management System
SIMOCRANE CMS Lean and CMS Basic
Standard package
Example of replay screen for hoist screen of STS crane
Example of replay screen for an RTG crane
The screens for the replay/playback function can be freely con-
figurable via Replay Configuration Editor. The Replay Configura-
tion Editor is integrated into SIMOCRANE CMS product Configu-
ration Editor. This enables the configuration of replay screens for
the replay function in runtime visualization. The replay function is
working complete independent from CMS RT function, which is
collecting the data continuously from field. The replay function is
working in parallel with CMS RT data acquisition and can be
switched on or off via graphical user interface any time the ope-
rator needs performing replay.
Replay Configuration Editor for replay screen configuration
With the Replay Configuration Editor, you can make the following
settings required for Replay:
•
Maximum number of archive tags; see the SIMOCRANE CMS
operating instructions.
•
Select the pictures to be prepared for Replay
•
Check one or more pictures prepared for Replay
•
Repair pictures prepared for Replay
•
Clean up tags that are no longer needed
•
Deselect pictures
•
You can expand and view the list of Picture Selector Tags
(read only)
The Replay Configuration Editor checks whether the require-
ments for Replay have been met every time a picture is selected
or repaired. The necessary tags and structures are checked for
completeness.
The following are required for Replay:
•
ReplayControl structure
•
Tags of the group ReplayControl with ReplayControl structure
tags
•
Tags of the Screens group that are relevant for Replay
•
Tags of the Settings group that are relevant for Replay
•
Tags of the ReplayControl group that are relevant for Replay
•
Picture selector tags
• ReplayArchive
Replay Configuration Editor – replay screen automatic generation of
modules by screen changes in WinCC project