SIEMENS
6/97
Siemens CR 1 · 2015
6
■
Technical specifications
(continued)
Drive systems
SIMOTRAS HD AC power controller
Option
H78
:
Operation at an ambient temperature higher than +65 °C is not
possible. The rated current, reduced compared to the standard
version, must be maintained across the entire temperature range
of 0 ... 65 °C.
Product designation
SIMOTRAS HD AC power controller
Type
6SG7070-
0EB60-0-Z
H78
6SG7072-
0EB60-0-Z
H78
6SG7076-
0EB60-0-Z
H78
6SG7080-
0EB60-0-Z
H78
6SG7082-
0EB60-0-Z
H78
6SG7085-
0EB60-0-Z
H78
110 ... 500 V 3 AC, 150 ... 700 A, ambient temperature 65 °C (option H78)
Rated supply voltage
Power unit
V
110 -10 % ... 500 + 10 % 3 AC
Rated frequency
Hz
50/60
The devices automatically adjust to the frequency of the applied line
voltage in a range from 45 ... 65 Hz.
Rated current
A
150
200
250
365
475
700
Rated supply voltage
Electronic power supply
V
380 (-25 %) ... 460 (+15 %) 2 AC
I
rated
= 1 A
or 190 (-25 %) ... 230 (+15 %) 1 AC
I
rated
= 2 A
(-35 % for 1 min.)
Phase fuse
1)
3 units
A/V
3NE1227-0
250/690
3NE1331-0
350/690
3NE1332-0
400/690
3NE1435-0
560/690
3NE3340-8
900/690
6RY1702-
0BA01
2)
1250/660
Rated supply voltage
Fan
V
400 (± 15 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz
400 (± 10 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz
Rated current
Fan
A
0.24
1.1
Overload possibility
3)
20 s duration:
I
= 2 ×
I
rated
then 70 s duration:
I
=
I
rated
then 60 s duration:
I
= 0 A
(cycle duration 150 s)
Power loss for rated current,
approx.
W
595
731
895
1280
2146
2865
Minimum load
A
10
10
10
15
15
15
Ambient temperature during ope-
ration at rated current
°C
0 ... 65
Cooling air requirement
m
3
/h
570
1400
2400
Sound pressure level
L
pA
(1 m)
dB
73
88
Storage and transport temperature
°C
-25 ... +70
Installation altitude above sea level
m
≤
1000 at rated current
max. 3500 with reduced voltage and current
Environmental class
DIN IEC 60721-3-3
3K3
Degree of protection
DIN EN 60529
IP00
IP00
IP00
IP00
IP00
IP00
D400 device type
225 Mre
285 Mre
360 Mre
525 Mre
680 Mre
900 Mre
Dimensions
See dimensional drawings
Weight, approx.
kg
30
30
30
45
85
137
1)
The fuses listed are not included with the device. The fuses listed are
recommended fuses that must be ordered separately.
2)
Fuses included with device. No semiconductor fuses are necessary.
3)
It is permissible to operate the device without interruption with the
rated connection current
I
rated
. This will cause the thyristors to reach
their limit temperature. It is not possible to accelerate, i.e. increase
the current from this operating state.
© Siemens AG 2015