SINAMICS S120 built-in devices
Basic Line Modules in booksize format
■
Overview
Basic Line Modules in booksize format
Basic Line Modules are used for applications in which no energy
is returned to the supply or where the energy exchange between
motor and generator axes takes place in the DC link. Basic Line
Modules can only feed energy from the supply system into the
DC link, energy cannot be fed back into the supply system. The
DC link voltage is directly derived from the 3-phase line voltage
via a 6-pulse bridge circuit. Basic Line Modules are designed for
connection to grounded, star TN/TT systems and non-grounded,
symmetrical IT systems. The connected Motor Modules are pre-
charged over the integrated pre-charging resistors (20 kW and
40 kW) or through activation of the thyristors (100 kW).
The 20 kW and 40 kW Basic Line Modules are equipped with an
integrated brake chopper. With the addition of an external bra-
king resistor, they can be used for applications with intermittent
regenerative operation such as stopping. A Braking Module is
required with a 100 kW Basic Line Module in addition to an ex-
ternal braking resistor for regenerative operation.
■
Design
The Basic Line Modules in booksize format feature the following
connections and interfaces as standard:
•
1 power connection
•
1 connection for the 24 V DC electronics power supply
•
1 DC link connection
•
3 DRIVE-CLiQ sockets
•
1 connection for braking resistor
(20 kW and 40 kW Basic Line Modules only)
•
1 temperature sensor input
The status of the Basic Line Modules is indicated via two multi-
color LEDs.
The scope of supply of the Basic Line Modules includes:
•
DRIVE-CLiQ cable for connection to the adjacent Control Unit
on the left for drive control, length 0.11 m (4.33 in)
•
DRIVE-CLiQ cable (length depends on module width) to con-
nect Basic Line Module to adjacent Motor Module,
length = width of Basic Line Module + 0.11 m (4.33 in)
•
Jumper for connecting the 24 V DC busbar to the adjacent
Motor Module
•
24 V terminal adapter (X24)
•
Connector X21
•
2 blanking plugs for sealing unused DRIVE-CLiQ sockets
•
1 set of warning signs in 30 languages
•
1 heat conducting foil
(for Basic Line Modules with cold platecooling only)
■
Selection and ordering data
Accessories
For technical specifications, selection and ordering data for
the associated line reactors, line filters and the recommended
line-side components, see Catalog PM 21, Chapter 3 "Basic Line
Modules in booksize format".
■
More information
For detailed technical information, see Catalog PM 21, Chapter
3 Basic Line Modules in booksize format.
Basic Line Modules
in booksize format
Description
Article No.
Line voltage 380 ... 480 V 3 AC
Internal air cooling
Rated supply power:
• 20 kW (25 hp)
6SL3130-1TE22-0AA0
• 40 kW (50 hp)
6SL3130-1TE24-0AA0
• 100 kW (125 HP)
6SL3130-1TE31-0AA0
Cold plate cooling
Rated supply power
• 20 kW (25 hp)
6SL3136-1TE22-0AA0
• 40 kW (50 hp)
6SL3136-1TE24-0AA0
• 100 kW (125 hp)
6SL3136-1TE31-0AA0